A novel toxicity fingerprinting method for pollutant identification with lux-marked biosensors

N. L. Turner, Alison Margaret Horsburgh, Graeme Iain Paton, Kenneth Stuart Killham, Andrew Alexander Meharg, S. Primrose, Norval James Colin Strachan

Research output: Contribution to journalArticle

12 Citations (Scopus)

Abstract

A novel technique is described for the identification and quantification of environmental pollutants based on toxicity fingerprinting with a metabolic lux-marked bacterial biosensor. This method involved characterizing the toxicity-based responses of the biosensor to seven calibration pollutants as acute temporal-dose response fingerprints. An algorithm is described to allow comparisons of responses of an unknown pollutant to be made against the calibration data. This is based on predicting pollutant concentration at each of six different time points over the course of a 5-min assay. If the prediction is consistent between the unknown pollutant and a calibration pollutant at the 95% test level, this is considered to be a positive identification. All seven calibration pollutants could be successfully distinguished from each other with this technique. Environmental samples, individually spiked with single concentrations of pollutants, were compared in this way against the calibration pollutants. An 83% identification success was achieved, with no false positives at the 95% test level. This is a simple and rapid technique that potentially can be applied to monitoring of industrial wastewater or as a screening tool for regulators.

Original languageEnglish
Pages (from-to)2456-2461
Number of pages5
JournalEnvironmental Toxicology and Chemistry
Volume20
DOIs
Publication statusPublished - 2001

Keywords

  • toxicity fingerprinting
  • lux-marked biosensor
  • PSEUDOMONAS-FLUORESCENS
  • OIL-SPILL
  • EFFLUENT
  • ASSAY

Cite this

A novel toxicity fingerprinting method for pollutant identification with lux-marked biosensors. / Turner, N. L.; Horsburgh, Alison Margaret; Paton, Graeme Iain; Killham, Kenneth Stuart; Meharg, Andrew Alexander; Primrose, S.; Strachan, Norval James Colin.

In: Environmental Toxicology and Chemistry, Vol. 20, 2001, p. 2456-2461.

Research output: Contribution to journalArticle

Turner, N. L. ; Horsburgh, Alison Margaret ; Paton, Graeme Iain ; Killham, Kenneth Stuart ; Meharg, Andrew Alexander ; Primrose, S. ; Strachan, Norval James Colin. / A novel toxicity fingerprinting method for pollutant identification with lux-marked biosensors. In: Environmental Toxicology and Chemistry. 2001 ; Vol. 20. pp. 2456-2461.
@article{019346a3e561421b90e6a370a5e2ebbc,
title = "A novel toxicity fingerprinting method for pollutant identification with lux-marked biosensors",
abstract = "A novel technique is described for the identification and quantification of environmental pollutants based on toxicity fingerprinting with a metabolic lux-marked bacterial biosensor. This method involved characterizing the toxicity-based responses of the biosensor to seven calibration pollutants as acute temporal-dose response fingerprints. An algorithm is described to allow comparisons of responses of an unknown pollutant to be made against the calibration data. This is based on predicting pollutant concentration at each of six different time points over the course of a 5-min assay. If the prediction is consistent between the unknown pollutant and a calibration pollutant at the 95{\%} test level, this is considered to be a positive identification. All seven calibration pollutants could be successfully distinguished from each other with this technique. Environmental samples, individually spiked with single concentrations of pollutants, were compared in this way against the calibration pollutants. An 83{\%} identification success was achieved, with no false positives at the 95{\%} test level. This is a simple and rapid technique that potentially can be applied to monitoring of industrial wastewater or as a screening tool for regulators.",
keywords = "toxicity fingerprinting, lux-marked biosensor, PSEUDOMONAS-FLUORESCENS, OIL-SPILL, EFFLUENT, ASSAY",
author = "Turner, {N. L.} and Horsburgh, {Alison Margaret} and Paton, {Graeme Iain} and Killham, {Kenneth Stuart} and Meharg, {Andrew Alexander} and S. Primrose and Strachan, {Norval James Colin}",
year = "2001",
doi = "10.1897/1551-5028(2001)020<2456:ANTFMF>2.0.CO;2",
language = "English",
volume = "20",
pages = "2456--2461",
journal = "Environmental Toxicology and Chemistry",
issn = "0730-7268",
publisher = "John Wiley and Sons Ltd",

}

TY - JOUR

T1 - A novel toxicity fingerprinting method for pollutant identification with lux-marked biosensors

AU - Turner, N. L.

AU - Horsburgh, Alison Margaret

AU - Paton, Graeme Iain

AU - Killham, Kenneth Stuart

AU - Meharg, Andrew Alexander

AU - Primrose, S.

AU - Strachan, Norval James Colin

PY - 2001

Y1 - 2001

N2 - A novel technique is described for the identification and quantification of environmental pollutants based on toxicity fingerprinting with a metabolic lux-marked bacterial biosensor. This method involved characterizing the toxicity-based responses of the biosensor to seven calibration pollutants as acute temporal-dose response fingerprints. An algorithm is described to allow comparisons of responses of an unknown pollutant to be made against the calibration data. This is based on predicting pollutant concentration at each of six different time points over the course of a 5-min assay. If the prediction is consistent between the unknown pollutant and a calibration pollutant at the 95% test level, this is considered to be a positive identification. All seven calibration pollutants could be successfully distinguished from each other with this technique. Environmental samples, individually spiked with single concentrations of pollutants, were compared in this way against the calibration pollutants. An 83% identification success was achieved, with no false positives at the 95% test level. This is a simple and rapid technique that potentially can be applied to monitoring of industrial wastewater or as a screening tool for regulators.

AB - A novel technique is described for the identification and quantification of environmental pollutants based on toxicity fingerprinting with a metabolic lux-marked bacterial biosensor. This method involved characterizing the toxicity-based responses of the biosensor to seven calibration pollutants as acute temporal-dose response fingerprints. An algorithm is described to allow comparisons of responses of an unknown pollutant to be made against the calibration data. This is based on predicting pollutant concentration at each of six different time points over the course of a 5-min assay. If the prediction is consistent between the unknown pollutant and a calibration pollutant at the 95% test level, this is considered to be a positive identification. All seven calibration pollutants could be successfully distinguished from each other with this technique. Environmental samples, individually spiked with single concentrations of pollutants, were compared in this way against the calibration pollutants. An 83% identification success was achieved, with no false positives at the 95% test level. This is a simple and rapid technique that potentially can be applied to monitoring of industrial wastewater or as a screening tool for regulators.

KW - toxicity fingerprinting

KW - lux-marked biosensor

KW - PSEUDOMONAS-FLUORESCENS

KW - OIL-SPILL

KW - EFFLUENT

KW - ASSAY

U2 - 10.1897/1551-5028(2001)020<2456:ANTFMF>2.0.CO;2

DO - 10.1897/1551-5028(2001)020<2456:ANTFMF>2.0.CO;2

M3 - Article

VL - 20

SP - 2456

EP - 2461

JO - Environmental Toxicology and Chemistry

JF - Environmental Toxicology and Chemistry

SN - 0730-7268

ER -