An evaluation of the Takeda UA751 automatic sphygmomanometer

Derek W Johnston, Deepti Shah

Research output: Contribution to journalArticle

3 Citations (Scopus)

Abstract

The Takeda UA751, a simple automatic blood pressure measuring device, was compared with standard osciltatory measurement. There was little or no systematic difference in pressure determined by the automatic or manual method and the correlation between the two devices for both systolic and distolic pressure was satisfactory. This suggests that the Takeda UA751 is an appropriate device for patient self monitoring of blood pressure or as a measure of pressure in group outcome trials. The results essential replicate an evaluation by Steptoe and Molineux (Behav. Res. Ther. 24 223-226, 1986) of an earlier version of the Takeda (the Copal UA251) that used a different method for determining blood pressure.
Original languageEnglish
Pages (from-to)203-204
Number of pages2
JournalBehaviour Research and Therapy
Volume27
Issue number2
DOIs
Publication statusPublished - 1989

Fingerprint

Sphygmomanometers
Blood Pressure
Equipment and Supplies
Sulindac
Pressure
Physiologic Monitoring

Keywords

  • Adolescent
  • Adult
  • Behavior Therapy
  • Blood Pressure Determination
  • Female
  • Humans
  • Hypertension
  • Male
  • Microcomputers
  • Signal Processing, Computer-Assisted

Cite this

An evaluation of the Takeda UA751 automatic sphygmomanometer. / Johnston, Derek W; Shah, Deepti.

In: Behaviour Research and Therapy, Vol. 27, No. 2, 1989, p. 203-204.

Research output: Contribution to journalArticle

@article{9d27e673915e41338526f558e52f6821,
title = "An evaluation of the Takeda UA751 automatic sphygmomanometer",
abstract = "The Takeda UA751, a simple automatic blood pressure measuring device, was compared with standard osciltatory measurement. There was little or no systematic difference in pressure determined by the automatic or manual method and the correlation between the two devices for both systolic and distolic pressure was satisfactory. This suggests that the Takeda UA751 is an appropriate device for patient self monitoring of blood pressure or as a measure of pressure in group outcome trials. The results essential replicate an evaluation by Steptoe and Molineux (Behav. Res. Ther. 24 223-226, 1986) of an earlier version of the Takeda (the Copal UA251) that used a different method for determining blood pressure.",
keywords = "Adolescent, Adult, Behavior Therapy, Blood Pressure Determination, Female, Humans, Hypertension, Male, Microcomputers, Signal Processing, Computer-Assisted",
author = "Johnston, {Derek W} and Deepti Shah",
year = "1989",
doi = "10.1016/0005-7967(89)90080-6",
language = "English",
volume = "27",
pages = "203--204",
journal = "Behaviour Research and Therapy",
issn = "0005-7967",
publisher = "Elsevier Limited",
number = "2",

}

TY - JOUR

T1 - An evaluation of the Takeda UA751 automatic sphygmomanometer

AU - Johnston, Derek W

AU - Shah, Deepti

PY - 1989

Y1 - 1989

N2 - The Takeda UA751, a simple automatic blood pressure measuring device, was compared with standard osciltatory measurement. There was little or no systematic difference in pressure determined by the automatic or manual method and the correlation between the two devices for both systolic and distolic pressure was satisfactory. This suggests that the Takeda UA751 is an appropriate device for patient self monitoring of blood pressure or as a measure of pressure in group outcome trials. The results essential replicate an evaluation by Steptoe and Molineux (Behav. Res. Ther. 24 223-226, 1986) of an earlier version of the Takeda (the Copal UA251) that used a different method for determining blood pressure.

AB - The Takeda UA751, a simple automatic blood pressure measuring device, was compared with standard osciltatory measurement. There was little or no systematic difference in pressure determined by the automatic or manual method and the correlation between the two devices for both systolic and distolic pressure was satisfactory. This suggests that the Takeda UA751 is an appropriate device for patient self monitoring of blood pressure or as a measure of pressure in group outcome trials. The results essential replicate an evaluation by Steptoe and Molineux (Behav. Res. Ther. 24 223-226, 1986) of an earlier version of the Takeda (the Copal UA251) that used a different method for determining blood pressure.

KW - Adolescent

KW - Adult

KW - Behavior Therapy

KW - Blood Pressure Determination

KW - Female

KW - Humans

KW - Hypertension

KW - Male

KW - Microcomputers

KW - Signal Processing, Computer-Assisted

U2 - 10.1016/0005-7967(89)90080-6

DO - 10.1016/0005-7967(89)90080-6

M3 - Article

VL - 27

SP - 203

EP - 204

JO - Behaviour Research and Therapy

JF - Behaviour Research and Therapy

SN - 0005-7967

IS - 2

ER -