Application of variable-rate selective excitation pulses for spin labeling in perfusion MRI

Jiabao He, Andrew M Blamire

Research output: Contribution to journalArticle

5 Citations (Scopus)

Abstract

Arterial spin labeling offers great potential in clinical applications for noninvasive measurement of cerebral blood flow. Arterial spin labeling tagging methods such as the flow sensitive alternating inversion recovery technique require efficient spatial inversion pulses with high inversion accuracy and sharp transition zones between inverted and noninverted magnetization, i.e., require a high performance inversion pulse. This work presents a comprehensive comparison of the advantages offered by a variable-rate selective excitation variant of the hyperbolic secant pulse against the widely used conventional hyperbolic secant pulse and the frequency offset corrected inversion pulses. Pulses were compared using simulation and experimental measurement in phantoms before being used in a flow sensitive alternating inversion recovery-arterial spin labeling perfusion measurement in normal volunteers. Both the hyperbolic secant and frequency offset corrected inversion pulses have small variations in inversion profiles that may lead to unwanted subtraction errors in arterial spin labeling at a level where the residual signal is comparable to the desired perfusion contrast. The variable-rate selective excitation pulse is shown to have improved inversion efficiency indicating its potential in perfusion MRI. The variable-rate selective excitation pulse variant also showed greatest tolerance to radiofrequency variation and off-resonance conditions, making it a robust choice for in vivo arterial spin labeling measurement.
Original languageEnglish
Pages (from-to)842-847
Number of pages6
JournalMagnetic Resonance in Medicine
Volume63
Issue number3
Early online date9 Feb 2010
DOIs
Publication statusPublished - Mar 2010

Fingerprint

Perfusion
Cerebrovascular Circulation
Healthy Volunteers

Keywords

  • RF pulses
  • perfusion
  • adiabatic pulse
  • pulsed arterial spin labeling
  • gradient modulation
  • FOCI
  • VERSE

Cite this

Application of variable-rate selective excitation pulses for spin labeling in perfusion MRI. / He, Jiabao; Blamire, Andrew M.

In: Magnetic Resonance in Medicine, Vol. 63, No. 3, 03.2010, p. 842-847.

Research output: Contribution to journalArticle

@article{dd2153edd1d24851b9c93a231a45eb64,
title = "Application of variable-rate selective excitation pulses for spin labeling in perfusion MRI",
abstract = "Arterial spin labeling offers great potential in clinical applications for noninvasive measurement of cerebral blood flow. Arterial spin labeling tagging methods such as the flow sensitive alternating inversion recovery technique require efficient spatial inversion pulses with high inversion accuracy and sharp transition zones between inverted and noninverted magnetization, i.e., require a high performance inversion pulse. This work presents a comprehensive comparison of the advantages offered by a variable-rate selective excitation variant of the hyperbolic secant pulse against the widely used conventional hyperbolic secant pulse and the frequency offset corrected inversion pulses. Pulses were compared using simulation and experimental measurement in phantoms before being used in a flow sensitive alternating inversion recovery-arterial spin labeling perfusion measurement in normal volunteers. Both the hyperbolic secant and frequency offset corrected inversion pulses have small variations in inversion profiles that may lead to unwanted subtraction errors in arterial spin labeling at a level where the residual signal is comparable to the desired perfusion contrast. The variable-rate selective excitation pulse is shown to have improved inversion efficiency indicating its potential in perfusion MRI. The variable-rate selective excitation pulse variant also showed greatest tolerance to radiofrequency variation and off-resonance conditions, making it a robust choice for in vivo arterial spin labeling measurement.",
keywords = "RF pulses, perfusion, adiabatic pulse, pulsed arterial spin labeling, gradient modulation, FOCI, VERSE",
author = "Jiabao He and Blamire, {Andrew M}",
note = "(c) 2010 Wiley-Liss, Inc.",
year = "2010",
month = "3",
doi = "10.1002/mrm.22251",
language = "English",
volume = "63",
pages = "842--847",
journal = "Magnetic Resonance in Medicine",
issn = "0740-3194",
publisher = "John Wiley and Sons Inc.",
number = "3",

}

TY - JOUR

T1 - Application of variable-rate selective excitation pulses for spin labeling in perfusion MRI

AU - He, Jiabao

AU - Blamire, Andrew M

N1 - (c) 2010 Wiley-Liss, Inc.

PY - 2010/3

Y1 - 2010/3

N2 - Arterial spin labeling offers great potential in clinical applications for noninvasive measurement of cerebral blood flow. Arterial spin labeling tagging methods such as the flow sensitive alternating inversion recovery technique require efficient spatial inversion pulses with high inversion accuracy and sharp transition zones between inverted and noninverted magnetization, i.e., require a high performance inversion pulse. This work presents a comprehensive comparison of the advantages offered by a variable-rate selective excitation variant of the hyperbolic secant pulse against the widely used conventional hyperbolic secant pulse and the frequency offset corrected inversion pulses. Pulses were compared using simulation and experimental measurement in phantoms before being used in a flow sensitive alternating inversion recovery-arterial spin labeling perfusion measurement in normal volunteers. Both the hyperbolic secant and frequency offset corrected inversion pulses have small variations in inversion profiles that may lead to unwanted subtraction errors in arterial spin labeling at a level where the residual signal is comparable to the desired perfusion contrast. The variable-rate selective excitation pulse is shown to have improved inversion efficiency indicating its potential in perfusion MRI. The variable-rate selective excitation pulse variant also showed greatest tolerance to radiofrequency variation and off-resonance conditions, making it a robust choice for in vivo arterial spin labeling measurement.

AB - Arterial spin labeling offers great potential in clinical applications for noninvasive measurement of cerebral blood flow. Arterial spin labeling tagging methods such as the flow sensitive alternating inversion recovery technique require efficient spatial inversion pulses with high inversion accuracy and sharp transition zones between inverted and noninverted magnetization, i.e., require a high performance inversion pulse. This work presents a comprehensive comparison of the advantages offered by a variable-rate selective excitation variant of the hyperbolic secant pulse against the widely used conventional hyperbolic secant pulse and the frequency offset corrected inversion pulses. Pulses were compared using simulation and experimental measurement in phantoms before being used in a flow sensitive alternating inversion recovery-arterial spin labeling perfusion measurement in normal volunteers. Both the hyperbolic secant and frequency offset corrected inversion pulses have small variations in inversion profiles that may lead to unwanted subtraction errors in arterial spin labeling at a level where the residual signal is comparable to the desired perfusion contrast. The variable-rate selective excitation pulse is shown to have improved inversion efficiency indicating its potential in perfusion MRI. The variable-rate selective excitation pulse variant also showed greatest tolerance to radiofrequency variation and off-resonance conditions, making it a robust choice for in vivo arterial spin labeling measurement.

KW - RF pulses

KW - perfusion

KW - adiabatic pulse

KW - pulsed arterial spin labeling

KW - gradient modulation

KW - FOCI

KW - VERSE

U2 - 10.1002/mrm.22251

DO - 10.1002/mrm.22251

M3 - Article

C2 - 20146373

VL - 63

SP - 842

EP - 847

JO - Magnetic Resonance in Medicine

JF - Magnetic Resonance in Medicine

SN - 0740-3194

IS - 3

ER -