Abstract

Using results previously reported for the spontaneous heating of bituminous coals, the Frank-Kamenetskii parameter is calculated in respect of each for the cubic reactant assembly used in the original experimental work. Comparisons are made with the results of other attempts to obtain this quantity by means of ignition experiments. (C) 1998 Published by Elsevier Science Ltd. All rights reserved.

Original languageEnglish
Pages (from-to)89-91
Number of pages3
JournalFuel
Volume78
Publication statusPublished - 1999

Keywords

  • Frank-Kamenetskii critical parameter
  • cubic reactant shape
  • bituminous coals

Cite this

@article{07693c6e783340958137e63daa0ab4f5,
title = "Calculation of the Frank-Kamenetskii critical parameter for a cubic reactant shape from experimental results on bituminous coals",
abstract = "Using results previously reported for the spontaneous heating of bituminous coals, the Frank-Kamenetskii parameter is calculated in respect of each for the cubic reactant assembly used in the original experimental work. Comparisons are made with the results of other attempts to obtain this quantity by means of ignition experiments. (C) 1998 Published by Elsevier Science Ltd. All rights reserved.",
keywords = "Frank-Kamenetskii critical parameter, cubic reactant shape, bituminous coals",
author = "Jones, {J C}",
year = "1999",
language = "English",
volume = "78",
pages = "89--91",
journal = "Fuel",
issn = "0016-2361",
publisher = "ELSEVIER APPL SCI PUBL LTD",

}

TY - JOUR

T1 - Calculation of the Frank-Kamenetskii critical parameter for a cubic reactant shape from experimental results on bituminous coals

AU - Jones, J C

PY - 1999

Y1 - 1999

N2 - Using results previously reported for the spontaneous heating of bituminous coals, the Frank-Kamenetskii parameter is calculated in respect of each for the cubic reactant assembly used in the original experimental work. Comparisons are made with the results of other attempts to obtain this quantity by means of ignition experiments. (C) 1998 Published by Elsevier Science Ltd. All rights reserved.

AB - Using results previously reported for the spontaneous heating of bituminous coals, the Frank-Kamenetskii parameter is calculated in respect of each for the cubic reactant assembly used in the original experimental work. Comparisons are made with the results of other attempts to obtain this quantity by means of ignition experiments. (C) 1998 Published by Elsevier Science Ltd. All rights reserved.