Comparison of two CE-ICP-MS interfaces and quantitative measurements of carboplatin in plasma samples using an internal standard

Charlotte Moller, Stefan Sturup, Helle Rusz Hansen, Bente Gammelgaard

Research output: Contribution to journalArticle

24 Citations (Scopus)

Abstract

Two commercially available CE-ICP-MS interfaces were investigated with respect to precision, limits of detection and ease-of-use. Our results demonstrate that the CEI-100 interface was more suited for the detection of carboplatin in our experimental set-up. A relative detection limit of 21 mu g Pt L-1 corresponding to an absolute detection limit of 0.1 fg Pt was found for the CEI-100 interface. The quantitative aspects of CE-ICP-MS were addressed and a method was developed using sodium diatrizoate as an internal standard added to the samples to correct for changes in sensitivity between runs. A significant improvement on the repeatability was obtained. The method was applied for the determination of free carboplatin in plasma incubations. The percentage of free carboplatin was calculated both based on the calibration curve and based on the fraction of free carboplatin relative to the total platinum area. Significantly different results were obtained using the two methods, probably due to adsorption of the plasma proteins to the incubation vial or to the capillary or due to formation of carboplatin adducts in concentrations below the limit of detection. This indicates a need for critical evaluation of the quantitative CE-ICP-MS measurements used for kinetic profiling.

Original languageEnglish
Pages (from-to)1208-1212
Number of pages5
JournalJournal of Analytical Atomic Spectrometry
Volume24
Issue number9
DOIs
Publication statusPublished - 1 Sep 2009

Keywords

  • human serum-proteins
  • mass-spectrometry
  • capillary-electrophoresis
  • monohydrated cisplatin
  • intact cisplatin
  • speciation
  • binding
  • complexes
  • metallodrugs
  • reactivity

Cite this

Comparison of two CE-ICP-MS interfaces and quantitative measurements of carboplatin in plasma samples using an internal standard. / Moller, Charlotte; Sturup, Stefan; Hansen, Helle Rusz; Gammelgaard, Bente.

In: Journal of Analytical Atomic Spectrometry, Vol. 24, No. 9, 01.09.2009, p. 1208-1212.

Research output: Contribution to journalArticle

Moller, Charlotte ; Sturup, Stefan ; Hansen, Helle Rusz ; Gammelgaard, Bente. / Comparison of two CE-ICP-MS interfaces and quantitative measurements of carboplatin in plasma samples using an internal standard. In: Journal of Analytical Atomic Spectrometry. 2009 ; Vol. 24, No. 9. pp. 1208-1212.
@article{1ab9476174024bc6b0c0f20fe9ed2d01,
title = "Comparison of two CE-ICP-MS interfaces and quantitative measurements of carboplatin in plasma samples using an internal standard",
abstract = "Two commercially available CE-ICP-MS interfaces were investigated with respect to precision, limits of detection and ease-of-use. Our results demonstrate that the CEI-100 interface was more suited for the detection of carboplatin in our experimental set-up. A relative detection limit of 21 mu g Pt L-1 corresponding to an absolute detection limit of 0.1 fg Pt was found for the CEI-100 interface. The quantitative aspects of CE-ICP-MS were addressed and a method was developed using sodium diatrizoate as an internal standard added to the samples to correct for changes in sensitivity between runs. A significant improvement on the repeatability was obtained. The method was applied for the determination of free carboplatin in plasma incubations. The percentage of free carboplatin was calculated both based on the calibration curve and based on the fraction of free carboplatin relative to the total platinum area. Significantly different results were obtained using the two methods, probably due to adsorption of the plasma proteins to the incubation vial or to the capillary or due to formation of carboplatin adducts in concentrations below the limit of detection. This indicates a need for critical evaluation of the quantitative CE-ICP-MS measurements used for kinetic profiling.",
keywords = "human serum-proteins, mass-spectrometry, capillary-electrophoresis, monohydrated cisplatin, intact cisplatin, speciation, binding, complexes, metallodrugs, reactivity",
author = "Charlotte Moller and Stefan Sturup and Hansen, {Helle Rusz} and Bente Gammelgaard",
year = "2009",
month = "9",
day = "1",
doi = "10.1039/b822857d",
language = "English",
volume = "24",
pages = "1208--1212",
journal = "Journal of Analytical Atomic Spectrometry",
issn = "0267-9477",
publisher = "The Royal Society of Chemistry",
number = "9",

}

TY - JOUR

T1 - Comparison of two CE-ICP-MS interfaces and quantitative measurements of carboplatin in plasma samples using an internal standard

AU - Moller, Charlotte

AU - Sturup, Stefan

AU - Hansen, Helle Rusz

AU - Gammelgaard, Bente

PY - 2009/9/1

Y1 - 2009/9/1

N2 - Two commercially available CE-ICP-MS interfaces were investigated with respect to precision, limits of detection and ease-of-use. Our results demonstrate that the CEI-100 interface was more suited for the detection of carboplatin in our experimental set-up. A relative detection limit of 21 mu g Pt L-1 corresponding to an absolute detection limit of 0.1 fg Pt was found for the CEI-100 interface. The quantitative aspects of CE-ICP-MS were addressed and a method was developed using sodium diatrizoate as an internal standard added to the samples to correct for changes in sensitivity between runs. A significant improvement on the repeatability was obtained. The method was applied for the determination of free carboplatin in plasma incubations. The percentage of free carboplatin was calculated both based on the calibration curve and based on the fraction of free carboplatin relative to the total platinum area. Significantly different results were obtained using the two methods, probably due to adsorption of the plasma proteins to the incubation vial or to the capillary or due to formation of carboplatin adducts in concentrations below the limit of detection. This indicates a need for critical evaluation of the quantitative CE-ICP-MS measurements used for kinetic profiling.

AB - Two commercially available CE-ICP-MS interfaces were investigated with respect to precision, limits of detection and ease-of-use. Our results demonstrate that the CEI-100 interface was more suited for the detection of carboplatin in our experimental set-up. A relative detection limit of 21 mu g Pt L-1 corresponding to an absolute detection limit of 0.1 fg Pt was found for the CEI-100 interface. The quantitative aspects of CE-ICP-MS were addressed and a method was developed using sodium diatrizoate as an internal standard added to the samples to correct for changes in sensitivity between runs. A significant improvement on the repeatability was obtained. The method was applied for the determination of free carboplatin in plasma incubations. The percentage of free carboplatin was calculated both based on the calibration curve and based on the fraction of free carboplatin relative to the total platinum area. Significantly different results were obtained using the two methods, probably due to adsorption of the plasma proteins to the incubation vial or to the capillary or due to formation of carboplatin adducts in concentrations below the limit of detection. This indicates a need for critical evaluation of the quantitative CE-ICP-MS measurements used for kinetic profiling.

KW - human serum-proteins

KW - mass-spectrometry

KW - capillary-electrophoresis

KW - monohydrated cisplatin

KW - intact cisplatin

KW - speciation

KW - binding

KW - complexes

KW - metallodrugs

KW - reactivity

U2 - 10.1039/b822857d

DO - 10.1039/b822857d

M3 - Article

VL - 24

SP - 1208

EP - 1212

JO - Journal of Analytical Atomic Spectrometry

JF - Journal of Analytical Atomic Spectrometry

SN - 0267-9477

IS - 9

ER -