Description and validation of the ActiReg: a novel instrument to measure physical activity and energy expenditure

Bo-Egil Hustvedt, Alf Christophersen, Lene R Johnsen, Heidi Tomten, Geraldine McNeill, Paul Haggarty, Arne Løvø

Research output: Contribution to journalArticle

57 Citations (Scopus)

Abstract

The ActiReg (PreMed AS, Oslo, Norway) system is unique in using combined recordings of body position and motion alone or combined with heart rate (HR) to calculate energy expenditure (EE) and express physical activity (PA). The ActiReg has two pairs of position and motion sensors connected by cables to a battery-operated storage unit fixed to a waist belt. Each pair of sensors was attached by medical tape to the chest and to the front of the right thigh respectively. The collected data were transferred to a personal computer and processed by a dedicated program ActiCalc. Calculation models for EE with and without HR are presented. The models were based on literature values for the energy costs of different activities and therefore require no calibration experiments. The ActiReg system was validated against doubly labelled water (DLW) and indirect calorimetry. The DLW validation demonstrated that neither EE calculated from ActiReg data alone (EEAR) nor from combined ActiReg and HR data (EEAR-HR) were statistically different from DLW results. The EEAR procedure causes some underestimation of EE >11 MJ corresponding to a PA level >2.0. This underestimation is reduced by the EEAR-HR procedure. The objective recording of the time spent in different body positions and at different levels of PA may be useful in studies of PA in different groups and in studies of whether recommendations for PA are being met. The comparative ease of data collection and calculation should make ActiReg a useful instrument to measure habitual PA level and EE.
Original languageEnglish
Pages (from-to)1001-1008
Number of pages8
JournalBritish Journal of Nutrition
Volume92
Issue number6
DOIs
Publication statusPublished - 2004

Keywords

  • energy expenditure
  • physical activity
  • activity pattern
  • doubly-labeled water
  • heart-rate
  • activity monitor
  • dose-response
  • body-weight
  • compendium
  • children
  • validity
  • walking
  • health

Cite this

Description and validation of the ActiReg : a novel instrument to measure physical activity and energy expenditure. / Hustvedt, Bo-Egil; Christophersen, Alf; Johnsen, Lene R; Tomten, Heidi; McNeill, Geraldine; Haggarty, Paul; Løvø, Arne.

In: British Journal of Nutrition, Vol. 92, No. 6, 2004, p. 1001-1008.

Research output: Contribution to journalArticle

Hustvedt, Bo-Egil ; Christophersen, Alf ; Johnsen, Lene R ; Tomten, Heidi ; McNeill, Geraldine ; Haggarty, Paul ; Løvø, Arne. / Description and validation of the ActiReg : a novel instrument to measure physical activity and energy expenditure. In: British Journal of Nutrition. 2004 ; Vol. 92, No. 6. pp. 1001-1008.
@article{a92a9464c7874917998cabc81a5dd477,
title = "Description and validation of the ActiReg: a novel instrument to measure physical activity and energy expenditure",
abstract = "The ActiReg (PreMed AS, Oslo, Norway) system is unique in using combined recordings of body position and motion alone or combined with heart rate (HR) to calculate energy expenditure (EE) and express physical activity (PA). The ActiReg has two pairs of position and motion sensors connected by cables to a battery-operated storage unit fixed to a waist belt. Each pair of sensors was attached by medical tape to the chest and to the front of the right thigh respectively. The collected data were transferred to a personal computer and processed by a dedicated program ActiCalc. Calculation models for EE with and without HR are presented. The models were based on literature values for the energy costs of different activities and therefore require no calibration experiments. The ActiReg system was validated against doubly labelled water (DLW) and indirect calorimetry. The DLW validation demonstrated that neither EE calculated from ActiReg data alone (EEAR) nor from combined ActiReg and HR data (EEAR-HR) were statistically different from DLW results. The EEAR procedure causes some underestimation of EE >11 MJ corresponding to a PA level >2.0. This underestimation is reduced by the EEAR-HR procedure. The objective recording of the time spent in different body positions and at different levels of PA may be useful in studies of PA in different groups and in studies of whether recommendations for PA are being met. The comparative ease of data collection and calculation should make ActiReg a useful instrument to measure habitual PA level and EE.",
keywords = "energy expenditure, physical activity, activity pattern, doubly-labeled water, heart-rate, activity monitor, dose-response, body-weight, compendium, children, validity, walking, health",
author = "Bo-Egil Hustvedt and Alf Christophersen and Johnsen, {Lene R} and Heidi Tomten and Geraldine McNeill and Paul Haggarty and Arne L{\o}v{\o}",
year = "2004",
doi = "10.1079/BJN20041272",
language = "English",
volume = "92",
pages = "1001--1008",
journal = "British Journal of Nutrition",
issn = "0007-1145",
publisher = "Cambridge Univ. Press.",
number = "6",

}

TY - JOUR

T1 - Description and validation of the ActiReg

T2 - a novel instrument to measure physical activity and energy expenditure

AU - Hustvedt, Bo-Egil

AU - Christophersen, Alf

AU - Johnsen, Lene R

AU - Tomten, Heidi

AU - McNeill, Geraldine

AU - Haggarty, Paul

AU - Løvø, Arne

PY - 2004

Y1 - 2004

N2 - The ActiReg (PreMed AS, Oslo, Norway) system is unique in using combined recordings of body position and motion alone or combined with heart rate (HR) to calculate energy expenditure (EE) and express physical activity (PA). The ActiReg has two pairs of position and motion sensors connected by cables to a battery-operated storage unit fixed to a waist belt. Each pair of sensors was attached by medical tape to the chest and to the front of the right thigh respectively. The collected data were transferred to a personal computer and processed by a dedicated program ActiCalc. Calculation models for EE with and without HR are presented. The models were based on literature values for the energy costs of different activities and therefore require no calibration experiments. The ActiReg system was validated against doubly labelled water (DLW) and indirect calorimetry. The DLW validation demonstrated that neither EE calculated from ActiReg data alone (EEAR) nor from combined ActiReg and HR data (EEAR-HR) were statistically different from DLW results. The EEAR procedure causes some underestimation of EE >11 MJ corresponding to a PA level >2.0. This underestimation is reduced by the EEAR-HR procedure. The objective recording of the time spent in different body positions and at different levels of PA may be useful in studies of PA in different groups and in studies of whether recommendations for PA are being met. The comparative ease of data collection and calculation should make ActiReg a useful instrument to measure habitual PA level and EE.

AB - The ActiReg (PreMed AS, Oslo, Norway) system is unique in using combined recordings of body position and motion alone or combined with heart rate (HR) to calculate energy expenditure (EE) and express physical activity (PA). The ActiReg has two pairs of position and motion sensors connected by cables to a battery-operated storage unit fixed to a waist belt. Each pair of sensors was attached by medical tape to the chest and to the front of the right thigh respectively. The collected data were transferred to a personal computer and processed by a dedicated program ActiCalc. Calculation models for EE with and without HR are presented. The models were based on literature values for the energy costs of different activities and therefore require no calibration experiments. The ActiReg system was validated against doubly labelled water (DLW) and indirect calorimetry. The DLW validation demonstrated that neither EE calculated from ActiReg data alone (EEAR) nor from combined ActiReg and HR data (EEAR-HR) were statistically different from DLW results. The EEAR procedure causes some underestimation of EE >11 MJ corresponding to a PA level >2.0. This underestimation is reduced by the EEAR-HR procedure. The objective recording of the time spent in different body positions and at different levels of PA may be useful in studies of PA in different groups and in studies of whether recommendations for PA are being met. The comparative ease of data collection and calculation should make ActiReg a useful instrument to measure habitual PA level and EE.

KW - energy expenditure

KW - physical activity

KW - activity pattern

KW - doubly-labeled water

KW - heart-rate

KW - activity monitor

KW - dose-response

KW - body-weight

KW - compendium

KW - children

KW - validity

KW - walking

KW - health

U2 - 10.1079/BJN20041272

DO - 10.1079/BJN20041272

M3 - Article

C2 - 15613263

VL - 92

SP - 1001

EP - 1008

JO - British Journal of Nutrition

JF - British Journal of Nutrition

SN - 0007-1145

IS - 6

ER -