Development of an anaerobic pyrolysis model for fire retardant cable sheathing materials

Artur Witkowski (Corresponding Author), Bertrand Girardin, Michael Forsth, Fiona Hewitt, Gaelle Fontaine, Sophie Duquesne, Serge Bourbigot, T. Richard Hull

Research output: Contribution to journalArticle

9 Citations (Scopus)

Abstract

Wire and cable coverings are potentially a major cause of fire in buildings and other installations. As they need to breach fire walls and are frequently located in vertical ducting, they have significant potential to increase the fire hazard. It is therefore important to understand the ignition and burning characteristics of cables by developing a model capable of predicting their burning behaviour for a range of scenarios. The fire performance of electrical cables is usually dominated by the fire performance of the sheathing materials. The complexity of the problem increases when cable sheathing incorporates fire retardants. One-dimensional pyrolysis models have been constructed for cable sheathing materials, based on milligram-scale and bench-scale test data by comparing the performance of three different software tools (ThermaKin, Comsol Multiphysics and FDS, version 6.0.1). Thermogravimetric analysis and differential scanning calorimetry were conducted on powdered cable coatings to determine the thermal degradation mechanism, the enthalpy of decomposition reactions, and the heat capacities of all apparent species. The emissivity and the in-depth absorption coefficient were determined using reflectance and transmittance measurements, with dispersive and non-dispersive spectrometers and integrating spheres. Bench-scale tests were conducted with a mass loss calorimeter flushed with nitrogen on samples in a horizontal orientation, for comparison with the pyrolysis model of non-flaming decomposition at an external heat flux of 50 kW m2. The parameters determined through analysis of the milligram-scale data were used to construct a pyrolysis model that predicted the total mass loss from calorimeter tests in anaerobic conditions. A condensed phase pyrolysis model that accurately predicts indepth temperature profiles of a solid fuel, and the mass flux of volatiles evolved during degradation of the fuel, is an essential component of a comprehensive fire model, which when coupled to a computational fluid dynamics code can be used to predict the burning processes in a fire scenario. Pyrolysis models vary considerably in complexity based on the assumptions incorporated into the development of the model.
Original languageEnglish
Pages (from-to)208-217
Number of pages10
JournalPolymer Degradation and Stability
Volume113
Early online date20 Jan 2015
Publication statusPublished - Mar 2015

Fingerprint

Cable sheathing
Flame retardants
Pyrolysis
Fires
Cables
Calorimeters
Decomposition
Fire hazards
Specific heat
Ignition
Thermogravimetric analysis
Spectrometers
Heat flux
Differential scanning calorimetry
Enthalpy
Computational fluid dynamics
Mass transfer
Wire
Nitrogen

Keywords

  • pyrolysis
  • thermal decomposition kinetics
  • thermophysical properties
  • polymer cable
  • modelling
  • fire retardant

Cite this

Witkowski, A., Girardin, B., Forsth, M., Hewitt, F., Fontaine, G., Duquesne, S., ... Hull, T. R. (2015). Development of an anaerobic pyrolysis model for fire retardant cable sheathing materials. Polymer Degradation and Stability, 113, 208-217.

Development of an anaerobic pyrolysis model for fire retardant cable sheathing materials. / Witkowski, Artur (Corresponding Author); Girardin, Bertrand; Forsth, Michael; Hewitt, Fiona; Fontaine, Gaelle ; Duquesne, Sophie; Bourbigot, Serge; Hull, T. Richard.

In: Polymer Degradation and Stability, Vol. 113, 03.2015, p. 208-217.

Research output: Contribution to journalArticle

Witkowski, A, Girardin, B, Forsth, M, Hewitt, F, Fontaine, G, Duquesne, S, Bourbigot, S & Hull, TR 2015, 'Development of an anaerobic pyrolysis model for fire retardant cable sheathing materials', Polymer Degradation and Stability, vol. 113, pp. 208-217.
Witkowski A, Girardin B, Forsth M, Hewitt F, Fontaine G, Duquesne S et al. Development of an anaerobic pyrolysis model for fire retardant cable sheathing materials. Polymer Degradation and Stability. 2015 Mar;113:208-217.
Witkowski, Artur ; Girardin, Bertrand ; Forsth, Michael ; Hewitt, Fiona ; Fontaine, Gaelle ; Duquesne, Sophie ; Bourbigot, Serge ; Hull, T. Richard. / Development of an anaerobic pyrolysis model for fire retardant cable sheathing materials. In: Polymer Degradation and Stability. 2015 ; Vol. 113. pp. 208-217.
@article{dda50842f31e46cc8b83b34763df4cfb,
title = "Development of an anaerobic pyrolysis model for fire retardant cable sheathing materials",
abstract = "Wire and cable coverings are potentially a major cause of fire in buildings and other installations. As they need to breach fire walls and are frequently located in vertical ducting, they have significant potential to increase the fire hazard. It is therefore important to understand the ignition and burning characteristics of cables by developing a model capable of predicting their burning behaviour for a range of scenarios. The fire performance of electrical cables is usually dominated by the fire performance of the sheathing materials. The complexity of the problem increases when cable sheathing incorporates fire retardants. One-dimensional pyrolysis models have been constructed for cable sheathing materials, based on milligram-scale and bench-scale test data by comparing the performance of three different software tools (ThermaKin, Comsol Multiphysics and FDS, version 6.0.1). Thermogravimetric analysis and differential scanning calorimetry were conducted on powdered cable coatings to determine the thermal degradation mechanism, the enthalpy of decomposition reactions, and the heat capacities of all apparent species. The emissivity and the in-depth absorption coefficient were determined using reflectance and transmittance measurements, with dispersive and non-dispersive spectrometers and integrating spheres. Bench-scale tests were conducted with a mass loss calorimeter flushed with nitrogen on samples in a horizontal orientation, for comparison with the pyrolysis model of non-flaming decomposition at an external heat flux of 50 kW m2. The parameters determined through analysis of the milligram-scale data were used to construct a pyrolysis model that predicted the total mass loss from calorimeter tests in anaerobic conditions. A condensed phase pyrolysis model that accurately predicts indepth temperature profiles of a solid fuel, and the mass flux of volatiles evolved during degradation of the fuel, is an essential component of a comprehensive fire model, which when coupled to a computational fluid dynamics code can be used to predict the burning processes in a fire scenario. Pyrolysis models vary considerably in complexity based on the assumptions incorporated into the development of the model.",
keywords = "pyrolysis, thermal decomposition kinetics, thermophysical properties, polymer cable, modelling, fire retardant",
author = "Artur Witkowski and Bertrand Girardin and Michael Forsth and Fiona Hewitt and Gaelle Fontaine and Sophie Duquesne and Serge Bourbigot and Hull, {T. Richard}",
note = "Maria Tengelin Nilsson and Anne Andersson at SP Measurement Technology performed the optical characterisation. Camille Le Bras at R2Fire conducted controlled atmosphere mass loss calorimetry. The research leading to these results has received funding from the European Union's Seventh Framework Programme (FP7/2007–2013) under grant agreement n° 308391. Bertrand Girardin and Fiona Hewitt are grateful for PhD studentships supported by this project.",
year = "2015",
month = "3",
language = "English",
volume = "113",
pages = "208--217",
journal = "Polymer Degradation and Stability",
publisher = "Elsevier",

}

TY - JOUR

T1 - Development of an anaerobic pyrolysis model for fire retardant cable sheathing materials

AU - Witkowski, Artur

AU - Girardin, Bertrand

AU - Forsth, Michael

AU - Hewitt, Fiona

AU - Fontaine, Gaelle

AU - Duquesne, Sophie

AU - Bourbigot, Serge

AU - Hull, T. Richard

N1 - Maria Tengelin Nilsson and Anne Andersson at SP Measurement Technology performed the optical characterisation. Camille Le Bras at R2Fire conducted controlled atmosphere mass loss calorimetry. The research leading to these results has received funding from the European Union's Seventh Framework Programme (FP7/2007–2013) under grant agreement n° 308391. Bertrand Girardin and Fiona Hewitt are grateful for PhD studentships supported by this project.

PY - 2015/3

Y1 - 2015/3

N2 - Wire and cable coverings are potentially a major cause of fire in buildings and other installations. As they need to breach fire walls and are frequently located in vertical ducting, they have significant potential to increase the fire hazard. It is therefore important to understand the ignition and burning characteristics of cables by developing a model capable of predicting their burning behaviour for a range of scenarios. The fire performance of electrical cables is usually dominated by the fire performance of the sheathing materials. The complexity of the problem increases when cable sheathing incorporates fire retardants. One-dimensional pyrolysis models have been constructed for cable sheathing materials, based on milligram-scale and bench-scale test data by comparing the performance of three different software tools (ThermaKin, Comsol Multiphysics and FDS, version 6.0.1). Thermogravimetric analysis and differential scanning calorimetry were conducted on powdered cable coatings to determine the thermal degradation mechanism, the enthalpy of decomposition reactions, and the heat capacities of all apparent species. The emissivity and the in-depth absorption coefficient were determined using reflectance and transmittance measurements, with dispersive and non-dispersive spectrometers and integrating spheres. Bench-scale tests were conducted with a mass loss calorimeter flushed with nitrogen on samples in a horizontal orientation, for comparison with the pyrolysis model of non-flaming decomposition at an external heat flux of 50 kW m2. The parameters determined through analysis of the milligram-scale data were used to construct a pyrolysis model that predicted the total mass loss from calorimeter tests in anaerobic conditions. A condensed phase pyrolysis model that accurately predicts indepth temperature profiles of a solid fuel, and the mass flux of volatiles evolved during degradation of the fuel, is an essential component of a comprehensive fire model, which when coupled to a computational fluid dynamics code can be used to predict the burning processes in a fire scenario. Pyrolysis models vary considerably in complexity based on the assumptions incorporated into the development of the model.

AB - Wire and cable coverings are potentially a major cause of fire in buildings and other installations. As they need to breach fire walls and are frequently located in vertical ducting, they have significant potential to increase the fire hazard. It is therefore important to understand the ignition and burning characteristics of cables by developing a model capable of predicting their burning behaviour for a range of scenarios. The fire performance of electrical cables is usually dominated by the fire performance of the sheathing materials. The complexity of the problem increases when cable sheathing incorporates fire retardants. One-dimensional pyrolysis models have been constructed for cable sheathing materials, based on milligram-scale and bench-scale test data by comparing the performance of three different software tools (ThermaKin, Comsol Multiphysics and FDS, version 6.0.1). Thermogravimetric analysis and differential scanning calorimetry were conducted on powdered cable coatings to determine the thermal degradation mechanism, the enthalpy of decomposition reactions, and the heat capacities of all apparent species. The emissivity and the in-depth absorption coefficient were determined using reflectance and transmittance measurements, with dispersive and non-dispersive spectrometers and integrating spheres. Bench-scale tests were conducted with a mass loss calorimeter flushed with nitrogen on samples in a horizontal orientation, for comparison with the pyrolysis model of non-flaming decomposition at an external heat flux of 50 kW m2. The parameters determined through analysis of the milligram-scale data were used to construct a pyrolysis model that predicted the total mass loss from calorimeter tests in anaerobic conditions. A condensed phase pyrolysis model that accurately predicts indepth temperature profiles of a solid fuel, and the mass flux of volatiles evolved during degradation of the fuel, is an essential component of a comprehensive fire model, which when coupled to a computational fluid dynamics code can be used to predict the burning processes in a fire scenario. Pyrolysis models vary considerably in complexity based on the assumptions incorporated into the development of the model.

KW - pyrolysis

KW - thermal decomposition kinetics

KW - thermophysical properties

KW - polymer cable

KW - modelling

KW - fire retardant

M3 - Article

VL - 113

SP - 208

EP - 217

JO - Polymer Degradation and Stability

JF - Polymer Degradation and Stability

ER -