Multi-frequency bioelectrical impedance analysis for assessing fat mass and fat-free mass in stroke or transient ischaemic attack patients

M W Kafri, J F Potter, P K Myint

Research output: Contribution to journalArticlepeer-review

20 Citations (Scopus)

Abstract

Background/Objectives:Dual energy X-ray absorptiometry (DEXA) is considered as the reference method in assessing fat-free and fat mass but is costly and not a pragmatic option in daily clinical practice. If devices based on multi-frequency bioelectrical impedance analysis (MF-BIA), which are cheaper and portable, are valid and reliable in measuring body composition, these could be used in routine clinical practice in nutritional management of patients and populations where malnutrition is prevalent.Subjects/Methods:A study of MF-BIA against DEXA in assessing fat-free and fat mass, and two internal validation studies of MF-BIA were conducted. Bland & Altman analysis to assess comparison against DEXA and Cronbach's α for internal validity were carried out.Results:Ten participants (mean age 66 years; 70% men) with a recent stroke or transient ischaemic attack (TIA) were recruited to assess against DEXA and the first internal validation. The second internal validation was based on 80 pairs of MF-BIA measurements in 40 stroke patients (mean age 70.3 years; 55% men) assessed at hospital admission and on discharge. There was a strong correlation between MF-BIA and DEXA (correlation coefficient was 0.88 for fat-free mass and 0.77 for fat mass). According to Bland & Altman analysis, MF-BIA and DEXA fat-free and fat mass estimates were similar. Internal consistency was high with Cronbach's-α >0.9.Conclusion:MF-BIA can be reliably used in stroke and TIA patients. The feasibility, clinical and cost effectiveness of MF-BIA in routine monitoring and management of malnutrition in stroke and TIA patients with high prevalence of nutritional deficits is worthy of further evaluation.European Journal of Clinical Nutrition advance online publication, 8 January 2014; doi:10.1038/ejcn.2013.266.
Original languageEnglish
Pages (from-to)677-682
Number of pages6
JournalEuropean Journal of Clinical Nutrition
Volume68
Issue number6
Early online date8 Jan 2014
DOIs
Publication statusPublished - Jun 2014

Keywords

  • multi-frequency bioelectrical impedance analysis (MF-BIA)
  • dual energy X-ray absorptiometry (DEXA)
  • fat-free mass
  • fat mass
  • validity

Fingerprint

Dive into the research topics of 'Multi-frequency bioelectrical impedance analysis for assessing fat mass and fat-free mass in stroke or transient ischaemic attack patients'. Together they form a unique fingerprint.

Cite this