Parallel-plate fluid flow systems for bone cell stimulation

Carmen Huesa, Miep H Helfrich, Richard M Aspden

Research output: Contribution to journalArticle

22 Citations (Scopus)

Abstract

Bone responds to changes in its mechanical environment, but the mechanisms by which it does so are poorly understood. One hypothesis of mechanosensing in bone states that osteocytes can sense the flow of fluid through the canalicular system. To study this in vitro a number of fluid flow devices have been designed in which cells are placed between parallel plates in sealed chambers. Fluid flows through the chambers at controlled rates, most commonly driven by a peristaltic pump. In addition to fluid flow, high pressures have been observed in these chambers, but the effect of this on the cellular responses has generally been ignored or considered irrelevant, something challenged by recent cellular experiments using pressure only. We have, therefore, devised a system in which we can considerably reduce the pressure while maintaining the flow rate to enable study of their effects individually and in combination. As reducing pressure also reduces the risk of leaks in flow chambers, our system is suitable for real-time microscopical experiments. We present details of the new systems and of experiments with osteoblasts to illustrate the effects of fluid flow with and without additional pressure on the translocation of beta-catenin to the nucleus.
Original languageEnglish
Pages (from-to)1182-1189
Number of pages8
JournalJournal of Biomechanics
Volume43
Issue number6
Early online date23 Dec 2009
DOIs
Publication statusPublished - 19 Apr 2010

Fingerprint

Flow of fluids
Bone
Pressure
Bone and Bones
Osteocytes
Experiments
Osteoblasts
beta Catenin
Flow rate
Pumps
Equipment and Supplies

Keywords

  • pressure
  • fluid flow
  • shear stress
  • bone

Cite this

Parallel-plate fluid flow systems for bone cell stimulation. / Huesa, Carmen; Helfrich, Miep H; Aspden, Richard M.

In: Journal of Biomechanics, Vol. 43, No. 6, 19.04.2010, p. 1182-1189.

Research output: Contribution to journalArticle

Huesa, Carmen ; Helfrich, Miep H ; Aspden, Richard M. / Parallel-plate fluid flow systems for bone cell stimulation. In: Journal of Biomechanics. 2010 ; Vol. 43, No. 6. pp. 1182-1189.
@article{4a487b3bffa64b659818614890fc11b8,
title = "Parallel-plate fluid flow systems for bone cell stimulation",
abstract = "Bone responds to changes in its mechanical environment, but the mechanisms by which it does so are poorly understood. One hypothesis of mechanosensing in bone states that osteocytes can sense the flow of fluid through the canalicular system. To study this in vitro a number of fluid flow devices have been designed in which cells are placed between parallel plates in sealed chambers. Fluid flows through the chambers at controlled rates, most commonly driven by a peristaltic pump. In addition to fluid flow, high pressures have been observed in these chambers, but the effect of this on the cellular responses has generally been ignored or considered irrelevant, something challenged by recent cellular experiments using pressure only. We have, therefore, devised a system in which we can considerably reduce the pressure while maintaining the flow rate to enable study of their effects individually and in combination. As reducing pressure also reduces the risk of leaks in flow chambers, our system is suitable for real-time microscopical experiments. We present details of the new systems and of experiments with osteoblasts to illustrate the effects of fluid flow with and without additional pressure on the translocation of beta-catenin to the nucleus.",
keywords = "pressure, fluid flow, shear stress, bone",
author = "Carmen Huesa and Helfrich, {Miep H} and Aspden, {Richard M}",
note = "Copyright 2009 Elsevier Ltd. All rights reserved.",
year = "2010",
month = "4",
day = "19",
doi = "10.1016/j.jbiomech.2009.11.029",
language = "English",
volume = "43",
pages = "1182--1189",
journal = "Journal of Biomechanics",
issn = "0021-9290",
publisher = "Elsevier Limited",
number = "6",

}

TY - JOUR

T1 - Parallel-plate fluid flow systems for bone cell stimulation

AU - Huesa, Carmen

AU - Helfrich, Miep H

AU - Aspden, Richard M

N1 - Copyright 2009 Elsevier Ltd. All rights reserved.

PY - 2010/4/19

Y1 - 2010/4/19

N2 - Bone responds to changes in its mechanical environment, but the mechanisms by which it does so are poorly understood. One hypothesis of mechanosensing in bone states that osteocytes can sense the flow of fluid through the canalicular system. To study this in vitro a number of fluid flow devices have been designed in which cells are placed between parallel plates in sealed chambers. Fluid flows through the chambers at controlled rates, most commonly driven by a peristaltic pump. In addition to fluid flow, high pressures have been observed in these chambers, but the effect of this on the cellular responses has generally been ignored or considered irrelevant, something challenged by recent cellular experiments using pressure only. We have, therefore, devised a system in which we can considerably reduce the pressure while maintaining the flow rate to enable study of their effects individually and in combination. As reducing pressure also reduces the risk of leaks in flow chambers, our system is suitable for real-time microscopical experiments. We present details of the new systems and of experiments with osteoblasts to illustrate the effects of fluid flow with and without additional pressure on the translocation of beta-catenin to the nucleus.

AB - Bone responds to changes in its mechanical environment, but the mechanisms by which it does so are poorly understood. One hypothesis of mechanosensing in bone states that osteocytes can sense the flow of fluid through the canalicular system. To study this in vitro a number of fluid flow devices have been designed in which cells are placed between parallel plates in sealed chambers. Fluid flows through the chambers at controlled rates, most commonly driven by a peristaltic pump. In addition to fluid flow, high pressures have been observed in these chambers, but the effect of this on the cellular responses has generally been ignored or considered irrelevant, something challenged by recent cellular experiments using pressure only. We have, therefore, devised a system in which we can considerably reduce the pressure while maintaining the flow rate to enable study of their effects individually and in combination. As reducing pressure also reduces the risk of leaks in flow chambers, our system is suitable for real-time microscopical experiments. We present details of the new systems and of experiments with osteoblasts to illustrate the effects of fluid flow with and without additional pressure on the translocation of beta-catenin to the nucleus.

KW - pressure

KW - fluid flow

KW - shear stress

KW - bone

U2 - 10.1016/j.jbiomech.2009.11.029

DO - 10.1016/j.jbiomech.2009.11.029

M3 - Article

VL - 43

SP - 1182

EP - 1189

JO - Journal of Biomechanics

JF - Journal of Biomechanics

SN - 0021-9290

IS - 6

ER -