Partial hepatectomy hemodynamics changes: Experimental data explained by closed-loop lumped modeling

Chloe Audebert, Mohamed Bekheit, Petru Bucur, Eric Vibert, Irene E. Vignon-Clementel* (Corresponding Author)

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

26 Citations (Scopus)

Abstract

The liver function may be degraded after partial liver ablation surgery. Adverse liver hemodynamics have been shown to be associated to liver failure. The link between these hemodynamics changes and ablation size is however poorly understood. This article proposes to explain with a closed-loop lumped model the hemodynamics changes observed during twelve surgeries in pigs. The portal venous tree is modeled with a pressure-dependent variable resistor. The variables measured, before liver ablation, are used to tune the model parameters. Then, the liver partial ablation is simulated with the model and the simulated pressures and flows are compared with post-operative measurements. Fluid infusion and blood losses occur during the surgery. The closed-loop model presented accounts for these blood volume changes. Moreover, the impact of blood volume changes and the liver lobe mass estimations on the simulated variables is studied. The typical increase of portal pressure, increase of liver pressure loss, slight decrease of portal flow and major decrease in arterial flow are quantitatively captured by the model for a 75% hepatectomy. It appears that the 75% decrease in hepatic arterial flow can be explained by the resistance increase induced by the surgery, and that no hepatic arterial buffer response (HABR) mechanism is needed to account for this change. The different post-operative states, observed in experiments, are reproduced with the proposed model. Thus, an explanation for inter-subjects post-operative variability is proposed. The presented framework can easily be adapted to other species circulations and to different pathologies for clinical hepatic applications.

Original languageEnglish
Pages (from-to)202-208
Number of pages7
JournalJournal of Biomechanics
Volume50
Early online date16 Nov 2016
DOIs
Publication statusPublished - 4 Jan 2017

Bibliographical note

This material is based upon work supported by the French National Agency for Research ANR-13-TECS-0006 iFLOW. The authors are grateful to the INRA Plateforme CIRE (Nouzilly, France) staff for their technical assistance in surgeries and imaging, and to Mylène Wartenberg for assistance in taking measurements.

Keywords

  • Closed-loop lumped model
  • Hemodynamics
  • Hepatectomy
  • Surgery simulation
  • Swine
  • Validation

Fingerprint

Dive into the research topics of 'Partial hepatectomy hemodynamics changes: Experimental data explained by closed-loop lumped modeling'. Together they form a unique fingerprint.

Cite this