Reproducibility and Diagnostic Accuracy of Kellgren-Lawrence Grading for Osteoarthritis Using Radiographs and Dual-Energy X-ray Absorptiometry Images

Kanako Yoshida, Rebecca J Barr, Sandro Galea-Soler, Richard M Aspden, David M Reid, Jennifer S Gregory

Research output: Contribution to journalArticle

12 Citations (Scopus)
34 Downloads (Pure)

Abstract

Advances in image quality from modern dual-energy X-ray absorptiometry (DXA) scanners now allow near radiograph-like quality images at a low radiation dose. This opens potential new applications for the use of DXA scanners to study other musculoskeletal conditions, such as osteoarthritis, which is often investigated by visual assessment of radiographs. Together, osteoporosis and osteoarthritis are the 2 most common musculoskeletal conditions, both of which primarily affect older people. The aim of this study was to determine whether Kellgren-Lawrence grading of DXA images can be used to grade hip osteoarthritis as effectively as radiographs. People who had attended for recent pelvic radiographs underwent DXA of hips (50 hips from 25 people) using a GE Healthcare iDXA scanner. Three observers assigned Kellgren-Lawrence grades to each image, and grading was repeated at least 1 week apart. Intraobserver and interobserver reliability for radiographs and DXA images were calculated using quadratic-weighted kappa (QWK). People were recalled 12 months later, and the tests were repeated with both the radiograph and DXA scans taken within 2 weeks of each other. Hip DXA intraobserver reproducibility achieved a QWK range of 0.88-0.95 and interobserver reproducibility of 0.85-0.88, similar to QWK from hip radiographs. Intraobserver reliability between subject-matched radiograph and iDXA images revealed QWK ranging between 0.80 and 0.88. Reproducibility of hip osteoarthritis grading using DXA was comparable with that of radiographs in this study and similar to repeatability scores previously published in literature. Given the lower radiation dose and the opportunity to simultaneously investigate osteoporosis, DXA presents an attractive imaging option for osteoarthritis.

Original languageEnglish
Pages (from-to)239-244
Number of pages6
JournalJournal of Clinical Densitometry
Volume18
Issue number2
Early online date8 Oct 2014
DOIs
Publication statusPublished - Apr 2015

Fingerprint

Photon Absorptiometry
Osteoarthritis
Hip
Hip Osteoarthritis
Osteoporosis
Radiation
Delivery of Health Care

Keywords

  • bone mineral density
  • DXA
  • Kellgren-Lawrence
  • osteoarthritis
  • osteoperosis

Cite this

Reproducibility and Diagnostic Accuracy of Kellgren-Lawrence Grading for Osteoarthritis Using Radiographs and Dual-Energy X-ray Absorptiometry Images. / Yoshida, Kanako; Barr, Rebecca J; Galea-Soler, Sandro; Aspden, Richard M; Reid, David M; Gregory, Jennifer S.

In: Journal of Clinical Densitometry, Vol. 18, No. 2, 04.2015, p. 239-244.

Research output: Contribution to journalArticle

@article{d3b453e01ac14343b5d1b3f9fd2ef238,
title = "Reproducibility and Diagnostic Accuracy of Kellgren-Lawrence Grading for Osteoarthritis Using Radiographs and Dual-Energy X-ray Absorptiometry Images",
abstract = "Advances in image quality from modern dual-energy X-ray absorptiometry (DXA) scanners now allow near radiograph-like quality images at a low radiation dose. This opens potential new applications for the use of DXA scanners to study other musculoskeletal conditions, such as osteoarthritis, which is often investigated by visual assessment of radiographs. Together, osteoporosis and osteoarthritis are the 2 most common musculoskeletal conditions, both of which primarily affect older people. The aim of this study was to determine whether Kellgren-Lawrence grading of DXA images can be used to grade hip osteoarthritis as effectively as radiographs. People who had attended for recent pelvic radiographs underwent DXA of hips (50 hips from 25 people) using a GE Healthcare iDXA scanner. Three observers assigned Kellgren-Lawrence grades to each image, and grading was repeated at least 1 week apart. Intraobserver and interobserver reliability for radiographs and DXA images were calculated using quadratic-weighted kappa (QWK). People were recalled 12 months later, and the tests were repeated with both the radiograph and DXA scans taken within 2 weeks of each other. Hip DXA intraobserver reproducibility achieved a QWK range of 0.88-0.95 and interobserver reproducibility of 0.85-0.88, similar to QWK from hip radiographs. Intraobserver reliability between subject-matched radiograph and iDXA images revealed QWK ranging between 0.80 and 0.88. Reproducibility of hip osteoarthritis grading using DXA was comparable with that of radiographs in this study and similar to repeatability scores previously published in literature. Given the lower radiation dose and the opportunity to simultaneously investigate osteoporosis, DXA presents an attractive imaging option for osteoarthritis.",
keywords = "bone mineral density , DXA, Kellgren-Lawrence, osteoarthritis, osteoperosis",
author = "Kanako Yoshida and Barr, {Rebecca J} and Sandro Galea-Soler and Aspden, {Richard M} and Reid, {David M} and Gregory, {Jennifer S}",
note = "Copyright {\circledC} 2014 The International Society for Clinical Densitometry. Published by Elsevier Inc. All rights reserved. The authors would like to thank all the study volunteers, radiographers Lana Gibson and Jennifer Scott as well as Carol McKerron for administrative support. The acquisition of scans was supported in part by an award (Ref: WHMSB_AU_068_071) from the Translational Medicine Research Initiative - a consortium made up of the Universities of Aberdeen, Dundee, Edinburgh and Glasgow, the four associated NHS Health Boards (Grampian, Tayside, Lothian and Greater Glasgow & Clyde), Scottish Enterprise and Pfizer. Kanako Yoshida is funded by the Grampian Osteoporosis Trust (GOT). Jennifer Gregory is supported by the Medical Research Council [G0901242].",
year = "2015",
month = "4",
doi = "10.1016/j.jocd.2014.08.003",
language = "English",
volume = "18",
pages = "239--244",
journal = "Journal of Clinical Densitometry",
issn = "1094-6950",
publisher = "Elsevier Inc.",
number = "2",

}

TY - JOUR

T1 - Reproducibility and Diagnostic Accuracy of Kellgren-Lawrence Grading for Osteoarthritis Using Radiographs and Dual-Energy X-ray Absorptiometry Images

AU - Yoshida, Kanako

AU - Barr, Rebecca J

AU - Galea-Soler, Sandro

AU - Aspden, Richard M

AU - Reid, David M

AU - Gregory, Jennifer S

N1 - Copyright © 2014 The International Society for Clinical Densitometry. Published by Elsevier Inc. All rights reserved. The authors would like to thank all the study volunteers, radiographers Lana Gibson and Jennifer Scott as well as Carol McKerron for administrative support. The acquisition of scans was supported in part by an award (Ref: WHMSB_AU_068_071) from the Translational Medicine Research Initiative - a consortium made up of the Universities of Aberdeen, Dundee, Edinburgh and Glasgow, the four associated NHS Health Boards (Grampian, Tayside, Lothian and Greater Glasgow & Clyde), Scottish Enterprise and Pfizer. Kanako Yoshida is funded by the Grampian Osteoporosis Trust (GOT). Jennifer Gregory is supported by the Medical Research Council [G0901242].

PY - 2015/4

Y1 - 2015/4

N2 - Advances in image quality from modern dual-energy X-ray absorptiometry (DXA) scanners now allow near radiograph-like quality images at a low radiation dose. This opens potential new applications for the use of DXA scanners to study other musculoskeletal conditions, such as osteoarthritis, which is often investigated by visual assessment of radiographs. Together, osteoporosis and osteoarthritis are the 2 most common musculoskeletal conditions, both of which primarily affect older people. The aim of this study was to determine whether Kellgren-Lawrence grading of DXA images can be used to grade hip osteoarthritis as effectively as radiographs. People who had attended for recent pelvic radiographs underwent DXA of hips (50 hips from 25 people) using a GE Healthcare iDXA scanner. Three observers assigned Kellgren-Lawrence grades to each image, and grading was repeated at least 1 week apart. Intraobserver and interobserver reliability for radiographs and DXA images were calculated using quadratic-weighted kappa (QWK). People were recalled 12 months later, and the tests were repeated with both the radiograph and DXA scans taken within 2 weeks of each other. Hip DXA intraobserver reproducibility achieved a QWK range of 0.88-0.95 and interobserver reproducibility of 0.85-0.88, similar to QWK from hip radiographs. Intraobserver reliability between subject-matched radiograph and iDXA images revealed QWK ranging between 0.80 and 0.88. Reproducibility of hip osteoarthritis grading using DXA was comparable with that of radiographs in this study and similar to repeatability scores previously published in literature. Given the lower radiation dose and the opportunity to simultaneously investigate osteoporosis, DXA presents an attractive imaging option for osteoarthritis.

AB - Advances in image quality from modern dual-energy X-ray absorptiometry (DXA) scanners now allow near radiograph-like quality images at a low radiation dose. This opens potential new applications for the use of DXA scanners to study other musculoskeletal conditions, such as osteoarthritis, which is often investigated by visual assessment of radiographs. Together, osteoporosis and osteoarthritis are the 2 most common musculoskeletal conditions, both of which primarily affect older people. The aim of this study was to determine whether Kellgren-Lawrence grading of DXA images can be used to grade hip osteoarthritis as effectively as radiographs. People who had attended for recent pelvic radiographs underwent DXA of hips (50 hips from 25 people) using a GE Healthcare iDXA scanner. Three observers assigned Kellgren-Lawrence grades to each image, and grading was repeated at least 1 week apart. Intraobserver and interobserver reliability for radiographs and DXA images were calculated using quadratic-weighted kappa (QWK). People were recalled 12 months later, and the tests were repeated with both the radiograph and DXA scans taken within 2 weeks of each other. Hip DXA intraobserver reproducibility achieved a QWK range of 0.88-0.95 and interobserver reproducibility of 0.85-0.88, similar to QWK from hip radiographs. Intraobserver reliability between subject-matched radiograph and iDXA images revealed QWK ranging between 0.80 and 0.88. Reproducibility of hip osteoarthritis grading using DXA was comparable with that of radiographs in this study and similar to repeatability scores previously published in literature. Given the lower radiation dose and the opportunity to simultaneously investigate osteoporosis, DXA presents an attractive imaging option for osteoarthritis.

KW - bone mineral density

KW - DXA

KW - Kellgren-Lawrence

KW - osteoarthritis

KW - osteoperosis

U2 - 10.1016/j.jocd.2014.08.003

DO - 10.1016/j.jocd.2014.08.003

M3 - Article

VL - 18

SP - 239

EP - 244

JO - Journal of Clinical Densitometry

JF - Journal of Clinical Densitometry

SN - 1094-6950

IS - 2

ER -