TY - JOUR
T1 - Sepsis scoring systems and use of the Sepsis six care bundle in maternity hospitals
AU - Abutheraa, Nouf
AU - Grant, June
AU - Mullen, Alexander B.
N1 - Acknowledgements
The authors are grateful for the assistance of healthcare staff who helped to identify septic patients throughout the study.
Funding
This study was sponsored by University of Strathclyde. Nouf Abutheraa received a financial scholarship funded by the Kingdom of Saudi Arabia government as part of her PhD studentship. The funding body had no role in the design of the study, the collection of the data, the analysis of findings, the interpretation of data or in the writing of this manuscript.
PY - 2021/7/23
Y1 - 2021/7/23
N2 - BackgroundThis study aimed to assess the predictive power of three different Sepsis Scoring Systems (SSSs), namely maternity Systematic Inflammatory Response Syndrome (mSIRS), quick Sepsis-related Organ Failure Assessment (qSOFA) and Modified Early Warning System (MEWS) in identifying sepsis by comparing them with positive culture. This study also sought to evaluate compliance with using the Sepsis Six Care Bundle (SSCB) operated in an individual health board.MethodsA retrospective cohort study was conducted in 3 maternity hospitals of a single Scottish health board that admitted 2690 pregnancies in a 12 weeks period in 2016. Data for study was obtained from medical notes, handheld and electronic health records for women who were prescribed antibiotics with a confirmed or suspected diagnosis of sepsis. Data on clinical parameters was used to classify women according to mSIRS, qSOFA and MEWS as having sepsis or not and this was compared to results of positive culture to obtain sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and area under Receiver Operating Characteristic curve (AUROC) along with their 95% confidence intervals. Data was also obtained on SSCB compliance.ResultsA total of 89 women were diagnosed with sepsis, of which 14 had missing data, leaving 75 for final analysis. Sensitivity, specificity, PPV, NPV and AUROC of mSIRS and MEWS were almost similar with AUROC of both being around 50%. Only 33 (37.1%) had identifiable sepsis six sticker displayed on medical notes and only 2 (2.2%) had all elements of SSCB delivered within the recommended one-hour post-diagnosis period. Blood culture and full blood count with other lab tests had been performed for most women (97%) followed by intravenous antibiotics and fluids (93.9%).ConclusionsmSIRS and MEWS were quite similar in detecting sepsis when compared to positive culture, with their ability to detect sepsis being close to chance. This underlines the need for creating a valid SSS with high sensitivity and specificity for clinical use in obstetric settings. Clinical use of SSCB was limited despite it being a health board policy, although there is considerable possibility of improvement following detailed audits and removal of barriers for implementing SSCB.
AB - BackgroundThis study aimed to assess the predictive power of three different Sepsis Scoring Systems (SSSs), namely maternity Systematic Inflammatory Response Syndrome (mSIRS), quick Sepsis-related Organ Failure Assessment (qSOFA) and Modified Early Warning System (MEWS) in identifying sepsis by comparing them with positive culture. This study also sought to evaluate compliance with using the Sepsis Six Care Bundle (SSCB) operated in an individual health board.MethodsA retrospective cohort study was conducted in 3 maternity hospitals of a single Scottish health board that admitted 2690 pregnancies in a 12 weeks period in 2016. Data for study was obtained from medical notes, handheld and electronic health records for women who were prescribed antibiotics with a confirmed or suspected diagnosis of sepsis. Data on clinical parameters was used to classify women according to mSIRS, qSOFA and MEWS as having sepsis or not and this was compared to results of positive culture to obtain sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and area under Receiver Operating Characteristic curve (AUROC) along with their 95% confidence intervals. Data was also obtained on SSCB compliance.ResultsA total of 89 women were diagnosed with sepsis, of which 14 had missing data, leaving 75 for final analysis. Sensitivity, specificity, PPV, NPV and AUROC of mSIRS and MEWS were almost similar with AUROC of both being around 50%. Only 33 (37.1%) had identifiable sepsis six sticker displayed on medical notes and only 2 (2.2%) had all elements of SSCB delivered within the recommended one-hour post-diagnosis period. Blood culture and full blood count with other lab tests had been performed for most women (97%) followed by intravenous antibiotics and fluids (93.9%).ConclusionsmSIRS and MEWS were quite similar in detecting sepsis when compared to positive culture, with their ability to detect sepsis being close to chance. This underlines the need for creating a valid SSS with high sensitivity and specificity for clinical use in obstetric settings. Clinical use of SSCB was limited despite it being a health board policy, although there is considerable possibility of improvement following detailed audits and removal of barriers for implementing SSCB.
KW - Sepsis
KW - sepsis scoring system
KW - sepsis diagnosis
KW - obstetric
KW - maternity
KW - systemic inflammatory response syndrome
KW - SIRS
KW - qSOFA
KW - MEWS
KW - early warning system
KW - sepsis six care bundle
UR - https://doi.org/10.1186/s12884-021-03921-3
U2 - 10.1186/s12884-021-03921-3
DO - 10.1186/s12884-021-03921-3
M3 - Article
VL - 21
JO - BMC Pregnancy and Childbirth
JF - BMC Pregnancy and Childbirth
SN - 1471-2393
M1 - 524
ER -