Species-specific isotope-ratio measurements of volatile tin and antimony compounds using capillary GC-ICP-time of flight MS

K. Haas, Jorg Feldmann, R. Wenrich, H. J. Stark

Research output: Contribution to journalArticlepeer-review

28 Citations (Scopus)

Abstract

The analytical performance of an axial inductively-coupled-plasma time-of-flight mass spectrometer (ICP-TOFMS) as a detector for fast transient chromatographic signals resulting from the coupling to capillary gas chromatography (CGC) was investigated. A cryotrapping GC-ICP-TOFMS method for the determination of volatile metal(loid) compounds (VOMs) in gases was used and the suitability of the TOF mass analyzer for multielemental speciation analysis and multi-isotope ratio determinations was studied in terms of accuracy and precision. Isotope ratios Sn-118/Sn-120 and Sb-121/Sb-123 have been determined in in-house gas standard atmospheres in Tedlar bags at two different levels (100 pg and I ng) for different elemental species (SnH4, MeSnH3, Me2SnH2, Me3SnH, BuSnH3, SbH3, and MeSbH2). A limitation arising from counting statistics in both detection modes could be shown. A solution containing rhodium (10 ng mL(-1)) and cadmium (40 ng mL(-1)) was introduced simultaneously to the GC outlet. Rhodium acts as a continuous internal standard and Cd is used for mass-bias correction (by measuring the Cd-111/Cd-113 ratio). The detection system in both pulse counting and analog mode was examined. The best attainable precision was established for Me2SnH2 (analog mode, 12 replicates, 1 ng, RSD 0.34%, accuracy 0.31%) whereas most other species ranged between 0.4 and 0.5% RSD if higher concentrations were used. The limitations of the pulse counting system are clearly seen, with peak heights of more than 2000 counts reaching saturation (for an integration time of 100 ms), which reduces the accuracy of isotope ratio determinations. A dozen VOM could be detected in an aged landfill gas sample; several unidentified Sn compounds were present. Although their isotope ratios are within the confidence value of the standards, it is not yet clear if the acquired precision is good enough to identify isotopic fractionation of metal(loid)s through biovolatilization processes. With the precision achieved, the combination of cryotrapping GC and ICP-TOFMS is a powerful tool for monitoring volatile multi-element species in multi-tracer experiments and isotope dilution methodology.

Original languageEnglish
Pages (from-to)587-596
Number of pages9
JournalFresenius’ Journal of Analytical Chemistry
Volume370
DOIs
Publication statusPublished - 2001

Keywords

  • MASS-SPECTROMETRY
  • GAS-CHROMATOGRAPHY
  • SPECIATION
  • METAL

Fingerprint

Dive into the research topics of 'Species-specific isotope-ratio measurements of volatile tin and antimony compounds using capillary GC-ICP-time of flight MS'. Together they form a unique fingerprint.

Cite this