Strategy for PLIF single-shot HCO imaging in turbulent methane/air flames

Bo Zhou, Johannes Kiefer, Johan Zetterberg, Zhongshan Li, Marcus Alden

Research output: Contribution to journalArticle

24 Citations (Scopus)

Abstract

Formyl (HCO) has since long been recognized as a common intermediate species and a potential local indicator of the major heat release in hydrocarbon combustion. Consequently, the detection of HCO is desirable especially in turbulent flames of practical relevance. However, due to the low concentration and low fluorescence quantum yield, single-shot based detection of HCO with planar laser-induced fluorescence (PLIF) has been a real challenge for experimentalists. In the present paper, a series of systematic investigations have been performed in order to develop a strategy for single-shot HCO PL1F detection in methane/air premixed flames. Potential spectral interference and applicable combustion conditions were analyzed in stable laminar flames employing fluorescence detection with high spectral and spatial resolution for different laser wavelengths. The wavelength 259.004 nm was identified as optimum in giving the maximum signal and minimum spectral interference from other species (e.g., OH and hot O-2). Photolytically generated HCO from formaldehyde (CH2O) was also observed, which restricts the applicable laser fluence to below 2.5 J/cm(2) in order to diminish the influence of CH2O down to 5 Besides, large hydrocarbon species generated in rich flames were found to contribute a considerable interference which can hardly be screened out. This limits the application of the HCO PLIF technique to lean premixed flames. Finally, by employing an optimized alexandrite laser system, single-shot HCO PLIF imaging in a turbulent methane/air flame is demonstrated, indicating the feasibility of further application of this technique to turbulent combustion systems. (C) 2013 The Combustion Institute. Published by Elsevier Inc. All rights reserved.
Original languageEnglish
Pages (from-to)1566-1574
Number of pages9
JournalCombustion and Flame
Volume161
Issue number6
Early online date16 Dec 2013
DOIs
Publication statusPublished - 1 Jun 2014

Fingerprint

Methane
laser induced fluorescence
shot
flames
methane
Fluorescence
Imaging techniques
Lasers
premixed flames
air
Air
interference
hydrocarbon combustion
alexandrite
Hydrocarbons
lasers
turbulent combustion
fluorescence
turbulent flames
formaldehyde

Keywords

  • Planar laser-induced fluorescence
  • Formyl radical
  • Heat release rate
  • Single-shot imaging
  • Turbulent flame
  • Spectral interference

Cite this

Strategy for PLIF single-shot HCO imaging in turbulent methane/air flames. / Zhou, Bo; Kiefer, Johannes; Zetterberg, Johan; Li, Zhongshan; Alden, Marcus.

In: Combustion and Flame, Vol. 161, No. 6, 01.06.2014, p. 1566-1574.

Research output: Contribution to journalArticle

Zhou, B, Kiefer, J, Zetterberg, J, Li, Z & Alden, M 2014, 'Strategy for PLIF single-shot HCO imaging in turbulent methane/air flames', Combustion and Flame, vol. 161, no. 6, pp. 1566-1574. https://doi.org/10.1016/j.combustflame.2013.11.019
Zhou, Bo ; Kiefer, Johannes ; Zetterberg, Johan ; Li, Zhongshan ; Alden, Marcus. / Strategy for PLIF single-shot HCO imaging in turbulent methane/air flames. In: Combustion and Flame. 2014 ; Vol. 161, No. 6. pp. 1566-1574.
@article{9d517ac02c9a484185e7093cc1763520,
title = "Strategy for PLIF single-shot HCO imaging in turbulent methane/air flames",
abstract = "Formyl (HCO) has since long been recognized as a common intermediate species and a potential local indicator of the major heat release in hydrocarbon combustion. Consequently, the detection of HCO is desirable especially in turbulent flames of practical relevance. However, due to the low concentration and low fluorescence quantum yield, single-shot based detection of HCO with planar laser-induced fluorescence (PLIF) has been a real challenge for experimentalists. In the present paper, a series of systematic investigations have been performed in order to develop a strategy for single-shot HCO PL1F detection in methane/air premixed flames. Potential spectral interference and applicable combustion conditions were analyzed in stable laminar flames employing fluorescence detection with high spectral and spatial resolution for different laser wavelengths. The wavelength 259.004 nm was identified as optimum in giving the maximum signal and minimum spectral interference from other species (e.g., OH and hot O-2). Photolytically generated HCO from formaldehyde (CH2O) was also observed, which restricts the applicable laser fluence to below 2.5 J/cm(2) in order to diminish the influence of CH2O down to 5 Besides, large hydrocarbon species generated in rich flames were found to contribute a considerable interference which can hardly be screened out. This limits the application of the HCO PLIF technique to lean premixed flames. Finally, by employing an optimized alexandrite laser system, single-shot HCO PLIF imaging in a turbulent methane/air flame is demonstrated, indicating the feasibility of further application of this technique to turbulent combustion systems. (C) 2013 The Combustion Institute. Published by Elsevier Inc. All rights reserved.",
keywords = "Planar laser-induced fluorescence, Formyl radical, Heat release rate, Single-shot imaging, Turbulent flame, Spectral interference",
author = "Bo Zhou and Johannes Kiefer and Johan Zetterberg and Zhongshan Li and Marcus Alden",
year = "2014",
month = "6",
day = "1",
doi = "10.1016/j.combustflame.2013.11.019",
language = "English",
volume = "161",
pages = "1566--1574",
journal = "Combustion and Flame",
issn = "0010-2180",
publisher = "Elsevier Inc.",
number = "6",

}

TY - JOUR

T1 - Strategy for PLIF single-shot HCO imaging in turbulent methane/air flames

AU - Zhou, Bo

AU - Kiefer, Johannes

AU - Zetterberg, Johan

AU - Li, Zhongshan

AU - Alden, Marcus

PY - 2014/6/1

Y1 - 2014/6/1

N2 - Formyl (HCO) has since long been recognized as a common intermediate species and a potential local indicator of the major heat release in hydrocarbon combustion. Consequently, the detection of HCO is desirable especially in turbulent flames of practical relevance. However, due to the low concentration and low fluorescence quantum yield, single-shot based detection of HCO with planar laser-induced fluorescence (PLIF) has been a real challenge for experimentalists. In the present paper, a series of systematic investigations have been performed in order to develop a strategy for single-shot HCO PL1F detection in methane/air premixed flames. Potential spectral interference and applicable combustion conditions were analyzed in stable laminar flames employing fluorescence detection with high spectral and spatial resolution for different laser wavelengths. The wavelength 259.004 nm was identified as optimum in giving the maximum signal and minimum spectral interference from other species (e.g., OH and hot O-2). Photolytically generated HCO from formaldehyde (CH2O) was also observed, which restricts the applicable laser fluence to below 2.5 J/cm(2) in order to diminish the influence of CH2O down to 5 Besides, large hydrocarbon species generated in rich flames were found to contribute a considerable interference which can hardly be screened out. This limits the application of the HCO PLIF technique to lean premixed flames. Finally, by employing an optimized alexandrite laser system, single-shot HCO PLIF imaging in a turbulent methane/air flame is demonstrated, indicating the feasibility of further application of this technique to turbulent combustion systems. (C) 2013 The Combustion Institute. Published by Elsevier Inc. All rights reserved.

AB - Formyl (HCO) has since long been recognized as a common intermediate species and a potential local indicator of the major heat release in hydrocarbon combustion. Consequently, the detection of HCO is desirable especially in turbulent flames of practical relevance. However, due to the low concentration and low fluorescence quantum yield, single-shot based detection of HCO with planar laser-induced fluorescence (PLIF) has been a real challenge for experimentalists. In the present paper, a series of systematic investigations have been performed in order to develop a strategy for single-shot HCO PL1F detection in methane/air premixed flames. Potential spectral interference and applicable combustion conditions were analyzed in stable laminar flames employing fluorescence detection with high spectral and spatial resolution for different laser wavelengths. The wavelength 259.004 nm was identified as optimum in giving the maximum signal and minimum spectral interference from other species (e.g., OH and hot O-2). Photolytically generated HCO from formaldehyde (CH2O) was also observed, which restricts the applicable laser fluence to below 2.5 J/cm(2) in order to diminish the influence of CH2O down to 5 Besides, large hydrocarbon species generated in rich flames were found to contribute a considerable interference which can hardly be screened out. This limits the application of the HCO PLIF technique to lean premixed flames. Finally, by employing an optimized alexandrite laser system, single-shot HCO PLIF imaging in a turbulent methane/air flame is demonstrated, indicating the feasibility of further application of this technique to turbulent combustion systems. (C) 2013 The Combustion Institute. Published by Elsevier Inc. All rights reserved.

KW - Planar laser-induced fluorescence

KW - Formyl radical

KW - Heat release rate

KW - Single-shot imaging

KW - Turbulent flame

KW - Spectral interference

U2 - 10.1016/j.combustflame.2013.11.019

DO - 10.1016/j.combustflame.2013.11.019

M3 - Article

VL - 161

SP - 1566

EP - 1574

JO - Combustion and Flame

JF - Combustion and Flame

SN - 0010-2180

IS - 6

ER -