Tract Sizes in Miniaturized Percutaneous Nephrolithotomy

A Systematic Review from the European Association of Urology Urolithiasis Guidelines Panel

Yasir Ruhayel, Abdulkadir Tepeler, Saeed Dabestani, Steven MacLennan, Aleš Petřík, Kemal Sarica, Christian Seitz, Andreas Skolarikos, Michael Straub, Christian Türk, Yuhong Yuan, Thomas Knoll

Research output: Contribution to journalArticle

15 Citations (Scopus)
6 Downloads (Pure)

Abstract

Context: Miniaturized instruments for percutaneous nephrolithotomy (PNL), utilizing tracts sized ≤22 Fr, have been developed in an effort to reduce the morbidity and increase the efficiency of stone removal compared with standard PNL (>22 Fr).
Objective: We systematically reviewed all available evidence on the efficacy and safety of miniaturized PNL for removing renal calculi.
Evidence acquisitionThe review was performed according to the Preferred Reporting Items for Systematic Reviews and Meta-analyses statement. Since it was not possible to perform a meta-analysis, the data were summarized in a narrative synthesis.
Evidence synthesis: After screening 2945 abstracts, 18 studies were included (two randomized controlled trials [RCTs], six nonrandomized comparative studies, and 10 case series). Thirteen studies were full-text articles and five were only available as congress abstracts. The size of tracts used in miniaturized procedures ranged from 22 Fr to 4.8 Fr. The largest mean stone size treated using small instruments was 980 mm2. Stone-free rates were comparable in miniaturized and standard PNL procedures. Procedures performed with small instruments tended to be associated with significantly lower blood loss, while the procedure duration tended to be significantly longer. Other complications were not notably different between PNL types. Study designs and populations were heterogeneous. Study limitations included selection and outcome reporting bias, as well as a lack of information on relevant confounding factors.
Conclusions: The studies suggest that miniaturized PNL is at least as efficacious and safe as standard PNL for the removal of renal calculi. However, the quality of the evidence was poor, drawn mainly from small studies, the majority of which were single-arm case series, and only two of which were RCTs. Furthermore, the tract sizes used and types of stones treated were heterogeneous. Hence, the risks of bias and confounding were high, highlighting the need for more reliable data from RCTs.Patient summaryRemoving kidney stones via percutaneous nephrolithotomy (PNL) using smaller sized instruments (mini-PNL) appears to be as effective and safe as using larger (traditional) instruments, but more clinical research is needed.
Original languageEnglish
Pages (from-to)220-235
Number of pages16
JournalEuropean Urology
Volume72
Issue number2
Early online date23 Feb 2017
DOIs
Publication statusPublished - Aug 2017

Fingerprint

Percutaneous Nephrostomy
Urolithiasis
Guidelines
Kidney Calculi
Randomized Controlled Trials
Meta-Analysis
Morbidity
Safety

Keywords

  • mini-perc
  • percutaneous nephrolithotomy
  • residual fragments
  • stone surgery
  • stenting
  • systematic review
  • urinary calculi

ASJC Scopus subject areas

  • Medicine(all)

Cite this

Tract Sizes in Miniaturized Percutaneous Nephrolithotomy : A Systematic Review from the European Association of Urology Urolithiasis Guidelines Panel. / Ruhayel, Yasir ; Tepeler, Abdulkadir ; Dabestani, Saeed; MacLennan, Steven; Petřík, Aleš ; Sarica, Kemal ; Seitz, Christian ; Skolarikos, Andreas; Straub, Michael; Türk, Christian ; Yuan, Yuhong ; Knoll, Thomas .

In: European Urology, Vol. 72, No. 2, 08.2017, p. 220-235.

Research output: Contribution to journalArticle

Ruhayel, Y, Tepeler, A, Dabestani, S, MacLennan, S, Petřík, A, Sarica, K, Seitz, C, Skolarikos, A, Straub, M, Türk, C, Yuan, Y & Knoll, T 2017, 'Tract Sizes in Miniaturized Percutaneous Nephrolithotomy: A Systematic Review from the European Association of Urology Urolithiasis Guidelines Panel', European Urology, vol. 72, no. 2, pp. 220-235. https://doi.org/10.1016/j.eururo.2017.01.046
Ruhayel, Yasir ; Tepeler, Abdulkadir ; Dabestani, Saeed ; MacLennan, Steven ; Petřík, Aleš ; Sarica, Kemal ; Seitz, Christian ; Skolarikos, Andreas ; Straub, Michael ; Türk, Christian ; Yuan, Yuhong ; Knoll, Thomas . / Tract Sizes in Miniaturized Percutaneous Nephrolithotomy : A Systematic Review from the European Association of Urology Urolithiasis Guidelines Panel. In: European Urology. 2017 ; Vol. 72, No. 2. pp. 220-235.
@article{e37d4e6344f44c369fd984eb5bbd8325,
title = "Tract Sizes in Miniaturized Percutaneous Nephrolithotomy: A Systematic Review from the European Association of Urology Urolithiasis Guidelines Panel",
abstract = "Context: Miniaturized instruments for percutaneous nephrolithotomy (PNL), utilizing tracts sized ≤22 Fr, have been developed in an effort to reduce the morbidity and increase the efficiency of stone removal compared with standard PNL (>22 Fr).Objective: We systematically reviewed all available evidence on the efficacy and safety of miniaturized PNL for removing renal calculi.Evidence acquisitionThe review was performed according to the Preferred Reporting Items for Systematic Reviews and Meta-analyses statement. Since it was not possible to perform a meta-analysis, the data were summarized in a narrative synthesis.Evidence synthesis: After screening 2945 abstracts, 18 studies were included (two randomized controlled trials [RCTs], six nonrandomized comparative studies, and 10 case series). Thirteen studies were full-text articles and five were only available as congress abstracts. The size of tracts used in miniaturized procedures ranged from 22 Fr to 4.8 Fr. The largest mean stone size treated using small instruments was 980 mm2. Stone-free rates were comparable in miniaturized and standard PNL procedures. Procedures performed with small instruments tended to be associated with significantly lower blood loss, while the procedure duration tended to be significantly longer. Other complications were not notably different between PNL types. Study designs and populations were heterogeneous. Study limitations included selection and outcome reporting bias, as well as a lack of information on relevant confounding factors.Conclusions: The studies suggest that miniaturized PNL is at least as efficacious and safe as standard PNL for the removal of renal calculi. However, the quality of the evidence was poor, drawn mainly from small studies, the majority of which were single-arm case series, and only two of which were RCTs. Furthermore, the tract sizes used and types of stones treated were heterogeneous. Hence, the risks of bias and confounding were high, highlighting the need for more reliable data from RCTs.Patient summaryRemoving kidney stones via percutaneous nephrolithotomy (PNL) using smaller sized instruments (mini-PNL) appears to be as effective and safe as using larger (traditional) instruments, but more clinical research is needed.",
keywords = "mini-perc, percutaneous nephrolithotomy, residual fragments, stone surgery, stenting, systematic review, urinary calculi",
author = "Yasir Ruhayel and Abdulkadir Tepeler and Saeed Dabestani and Steven MacLennan and Aleš Petř{\'i}k and Kemal Sarica and Christian Seitz and Andreas Skolarikos and Michael Straub and Christian T{\"u}rk and Yuhong Yuan and Thomas Knoll",
note = "Funding/Support and role of the sponsor: None. Acknowledgments: We are grateful for the valuable help of Karin Plass, European Association of Urology Guidelines Office, Arnhem, The Netherlands, for providing administrative support. We also thank Richard Sylvester and Thomas Lam, of the EAU Guidelines Office, for providing methodological supervision and support.",
year = "2017",
month = "8",
doi = "10.1016/j.eururo.2017.01.046",
language = "English",
volume = "72",
pages = "220--235",
journal = "European Urology",
issn = "0302-2838",
publisher = "Elsevier",
number = "2",

}

TY - JOUR

T1 - Tract Sizes in Miniaturized Percutaneous Nephrolithotomy

T2 - A Systematic Review from the European Association of Urology Urolithiasis Guidelines Panel

AU - Ruhayel, Yasir

AU - Tepeler, Abdulkadir

AU - Dabestani, Saeed

AU - MacLennan, Steven

AU - Petřík, Aleš

AU - Sarica, Kemal

AU - Seitz, Christian

AU - Skolarikos, Andreas

AU - Straub, Michael

AU - Türk, Christian

AU - Yuan, Yuhong

AU - Knoll, Thomas

N1 - Funding/Support and role of the sponsor: None. Acknowledgments: We are grateful for the valuable help of Karin Plass, European Association of Urology Guidelines Office, Arnhem, The Netherlands, for providing administrative support. We also thank Richard Sylvester and Thomas Lam, of the EAU Guidelines Office, for providing methodological supervision and support.

PY - 2017/8

Y1 - 2017/8

N2 - Context: Miniaturized instruments for percutaneous nephrolithotomy (PNL), utilizing tracts sized ≤22 Fr, have been developed in an effort to reduce the morbidity and increase the efficiency of stone removal compared with standard PNL (>22 Fr).Objective: We systematically reviewed all available evidence on the efficacy and safety of miniaturized PNL for removing renal calculi.Evidence acquisitionThe review was performed according to the Preferred Reporting Items for Systematic Reviews and Meta-analyses statement. Since it was not possible to perform a meta-analysis, the data were summarized in a narrative synthesis.Evidence synthesis: After screening 2945 abstracts, 18 studies were included (two randomized controlled trials [RCTs], six nonrandomized comparative studies, and 10 case series). Thirteen studies were full-text articles and five were only available as congress abstracts. The size of tracts used in miniaturized procedures ranged from 22 Fr to 4.8 Fr. The largest mean stone size treated using small instruments was 980 mm2. Stone-free rates were comparable in miniaturized and standard PNL procedures. Procedures performed with small instruments tended to be associated with significantly lower blood loss, while the procedure duration tended to be significantly longer. Other complications were not notably different between PNL types. Study designs and populations were heterogeneous. Study limitations included selection and outcome reporting bias, as well as a lack of information on relevant confounding factors.Conclusions: The studies suggest that miniaturized PNL is at least as efficacious and safe as standard PNL for the removal of renal calculi. However, the quality of the evidence was poor, drawn mainly from small studies, the majority of which were single-arm case series, and only two of which were RCTs. Furthermore, the tract sizes used and types of stones treated were heterogeneous. Hence, the risks of bias and confounding were high, highlighting the need for more reliable data from RCTs.Patient summaryRemoving kidney stones via percutaneous nephrolithotomy (PNL) using smaller sized instruments (mini-PNL) appears to be as effective and safe as using larger (traditional) instruments, but more clinical research is needed.

AB - Context: Miniaturized instruments for percutaneous nephrolithotomy (PNL), utilizing tracts sized ≤22 Fr, have been developed in an effort to reduce the morbidity and increase the efficiency of stone removal compared with standard PNL (>22 Fr).Objective: We systematically reviewed all available evidence on the efficacy and safety of miniaturized PNL for removing renal calculi.Evidence acquisitionThe review was performed according to the Preferred Reporting Items for Systematic Reviews and Meta-analyses statement. Since it was not possible to perform a meta-analysis, the data were summarized in a narrative synthesis.Evidence synthesis: After screening 2945 abstracts, 18 studies were included (two randomized controlled trials [RCTs], six nonrandomized comparative studies, and 10 case series). Thirteen studies were full-text articles and five were only available as congress abstracts. The size of tracts used in miniaturized procedures ranged from 22 Fr to 4.8 Fr. The largest mean stone size treated using small instruments was 980 mm2. Stone-free rates were comparable in miniaturized and standard PNL procedures. Procedures performed with small instruments tended to be associated with significantly lower blood loss, while the procedure duration tended to be significantly longer. Other complications were not notably different between PNL types. Study designs and populations were heterogeneous. Study limitations included selection and outcome reporting bias, as well as a lack of information on relevant confounding factors.Conclusions: The studies suggest that miniaturized PNL is at least as efficacious and safe as standard PNL for the removal of renal calculi. However, the quality of the evidence was poor, drawn mainly from small studies, the majority of which were single-arm case series, and only two of which were RCTs. Furthermore, the tract sizes used and types of stones treated were heterogeneous. Hence, the risks of bias and confounding were high, highlighting the need for more reliable data from RCTs.Patient summaryRemoving kidney stones via percutaneous nephrolithotomy (PNL) using smaller sized instruments (mini-PNL) appears to be as effective and safe as using larger (traditional) instruments, but more clinical research is needed.

KW - mini-perc

KW - percutaneous nephrolithotomy

KW - residual fragments

KW - stone surgery

KW - stenting

KW - systematic review

KW - urinary calculi

U2 - 10.1016/j.eururo.2017.01.046

DO - 10.1016/j.eururo.2017.01.046

M3 - Article

VL - 72

SP - 220

EP - 235

JO - European Urology

JF - European Urology

SN - 0302-2838

IS - 2

ER -