True colour imaging of the fundus using a scanning laser ophthalmoscope

P. Vieira, Ayyakkannu Manivannan, Peter Frederick Sharp, John Vincent Forrester

Research output: Contribution to journalArticle

8 Citations (Scopus)

Abstract

Currently retinal imaging is performed with the fundus camera. This has a number of limitations, in particular the high level of illuminations required for imaging. The scanning laser ophthalmoscope (SLO) has been proposed as an alternative imaging device but to date one of its main limitations has been that it gives only monochromatic images. In this paper we describe an SLO which uses low power red, green and blue lasers to image the human fundus. Using three lasers simultaneously to produce a colour image will increase the fundus exposure by a factor of three. To overcome this problem, a technique has been developed for multiplexing, the lasers so that each point on the retina is imaged by the three lasers pulsed rapidly in sequence. The total exposure is thus kept to the same level as for a single laser and total imaging time is not increased. An example is shown of the image from a patient with diabetic retinopathy.

Original languageEnglish
Pages (from-to)1-10
Number of pages9
JournalPhysiological Measurement
Volume23
Issue number1
DOIs
Publication statusPublished - Feb 2002

Keywords

  • scanning laser ophthalmoscope
  • retina
  • fundus imaging
  • digital colour fundus images
  • RGB imaging
  • diagnosis

Cite this

True colour imaging of the fundus using a scanning laser ophthalmoscope. / Vieira, P.; Manivannan, Ayyakkannu; Sharp, Peter Frederick; Forrester, John Vincent.

In: Physiological Measurement, Vol. 23, No. 1, 02.2002, p. 1-10.

Research output: Contribution to journalArticle

Vieira, P. ; Manivannan, Ayyakkannu ; Sharp, Peter Frederick ; Forrester, John Vincent. / True colour imaging of the fundus using a scanning laser ophthalmoscope. In: Physiological Measurement. 2002 ; Vol. 23, No. 1. pp. 1-10.
@article{fe944958861143ddabbd6f390eaea968,
title = "True colour imaging of the fundus using a scanning laser ophthalmoscope",
abstract = "Currently retinal imaging is performed with the fundus camera. This has a number of limitations, in particular the high level of illuminations required for imaging. The scanning laser ophthalmoscope (SLO) has been proposed as an alternative imaging device but to date one of its main limitations has been that it gives only monochromatic images. In this paper we describe an SLO which uses low power red, green and blue lasers to image the human fundus. Using three lasers simultaneously to produce a colour image will increase the fundus exposure by a factor of three. To overcome this problem, a technique has been developed for multiplexing, the lasers so that each point on the retina is imaged by the three lasers pulsed rapidly in sequence. The total exposure is thus kept to the same level as for a single laser and total imaging time is not increased. An example is shown of the image from a patient with diabetic retinopathy.",
keywords = "scanning laser ophthalmoscope, retina, fundus imaging, digital colour fundus images, RGB imaging, diagnosis",
author = "P. Vieira and Ayyakkannu Manivannan and Sharp, {Peter Frederick} and Forrester, {John Vincent}",
year = "2002",
month = "2",
doi = "10.1088/0967-3334/23/1/301",
language = "English",
volume = "23",
pages = "1--10",
journal = "Physiological Measurement",
issn = "0967-3334",
publisher = "IOP Publishing Ltd.",
number = "1",

}

TY - JOUR

T1 - True colour imaging of the fundus using a scanning laser ophthalmoscope

AU - Vieira, P.

AU - Manivannan, Ayyakkannu

AU - Sharp, Peter Frederick

AU - Forrester, John Vincent

PY - 2002/2

Y1 - 2002/2

N2 - Currently retinal imaging is performed with the fundus camera. This has a number of limitations, in particular the high level of illuminations required for imaging. The scanning laser ophthalmoscope (SLO) has been proposed as an alternative imaging device but to date one of its main limitations has been that it gives only monochromatic images. In this paper we describe an SLO which uses low power red, green and blue lasers to image the human fundus. Using three lasers simultaneously to produce a colour image will increase the fundus exposure by a factor of three. To overcome this problem, a technique has been developed for multiplexing, the lasers so that each point on the retina is imaged by the three lasers pulsed rapidly in sequence. The total exposure is thus kept to the same level as for a single laser and total imaging time is not increased. An example is shown of the image from a patient with diabetic retinopathy.

AB - Currently retinal imaging is performed with the fundus camera. This has a number of limitations, in particular the high level of illuminations required for imaging. The scanning laser ophthalmoscope (SLO) has been proposed as an alternative imaging device but to date one of its main limitations has been that it gives only monochromatic images. In this paper we describe an SLO which uses low power red, green and blue lasers to image the human fundus. Using three lasers simultaneously to produce a colour image will increase the fundus exposure by a factor of three. To overcome this problem, a technique has been developed for multiplexing, the lasers so that each point on the retina is imaged by the three lasers pulsed rapidly in sequence. The total exposure is thus kept to the same level as for a single laser and total imaging time is not increased. An example is shown of the image from a patient with diabetic retinopathy.

KW - scanning laser ophthalmoscope

KW - retina

KW - fundus imaging

KW - digital colour fundus images

KW - RGB imaging

KW - diagnosis

U2 - 10.1088/0967-3334/23/1/301

DO - 10.1088/0967-3334/23/1/301

M3 - Article

VL - 23

SP - 1

EP - 10

JO - Physiological Measurement

JF - Physiological Measurement

SN - 0967-3334

IS - 1

ER -